IBM System x3650 M4 BD Type 5466 Installation And Service Manual page 612

Table of Contents

Advertisement

I.2018003 • I.3818001
I.2018003
[I.2018003] A bad option ROM checksum was detected for the device found at Bus % Device %
Function %. The Vendor ID for the device is % and the Device ID is %.
Explanation: ROM CHECKSUM ERROR
Severity: Error
User response: Complete the following steps:
1.
If this PCIe device and/or any attached cables were recently installed, moved, serviced or upgraded, reseat
adapter and any attached cables.
2.
Move adapter to a different system slot, if available.
3.
Check IBM support site for any applicable service bulletin or UEFI or adapter firmware update that applies to
this error. NOTE: It may be necessary to configure slot to Gen1 or to use special utility software so that adapter
firmware can be upgraded. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings -> Devices and
I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed Selection, or the ASU Utility.
4.
Replace adapter.
I.3048005
[I.3048005] UEFI has booted from the backup flash bank.
Explanation: Booting Backup UEFI Image
Severity: Info
User response: Complete the following steps:
1.
Refer to service information for this product section on UEFI Recovery to return system to primary bank.
I.3808004
[I.3808004] The IMM System Event log (SEL) is full.
Explanation: IPMI System Event Log is Full
Severity: Info
User response: Complete the following steps:
1.
Use F1 Setup to access System Event Logs Menu and Choose Clear IMM System Event Log and Restart Server.
I.3818001
[I.3818001] The firmware image capsule signature for the currently booted flash bank is invalid.
Explanation: Current Bank CRTM Capsule Update Signature Invalid
Severity: Info
User response: Complete the following steps:
1.
Reboot system. Will come up on backup UEFI image. Reflash the primary UEFI image.
2.
If error does not persist no additional recovery action is required.
3.
If error persists, or boot is unsuccessful, (Trained service technician only) Replace the system board.
596
System x3650 M4 BD Type 5466: Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents