IBM System x3650 M4 BD Type 5466 Installation And Service Manual page 24

Table of Contents

Advertisement

ServeRAID controller upgrade:
Environment:
Electrical input with hot-swap ac power supplies:
8
System x3650 M4 BD Type 5466: Installation and Service Guide
v M5210 SAS/SATA Controller for IBM System x
v N2115 SAS/SATA HBA for IBM System x
v IBM 6Gb Performance Optimized HBA
v ServeRAID M5100 Series 512MB Cache/RAID 5 Upgrade for IBM
System x
v ServeRAID M5100 Series 512MB Flash/RAID 5 Upgrade for IBM System
x
v ServeRAID M1100 Series Zero Cache/RAID 5 Upgrade for IBM System x
v ServeRAID M5100 Series Zero Cache/RAID 5 Upgrade for IBM System x
v ServeRAID M5100 Series RAID 6 Upgrade for IBM System x
v ServeRAID M5100 Series 1GB Flash/RAID Upgrade for IBM System x
v ServeRAID M5100 Series 2GB Cache/RAID 5 Upgrade for IBM System x
For more information on Features on Demand (FoD), including instructions
for automating the activation and installation of the activation key by
using IBM ToolsCenter or IBM Director, see the IBM System x Features on
Demand User's Guide at under the Help section.
v Air temperature:
– Server on: 5°C to 40°C (41°F to 104°F); altitude: 0 to 915 m (3000 ft).
– Server on: 5°C to 32°C (41°F to 89.6°F); altitude: 915 m (3000 ft) to
2134 m (7000 ft).
– Server on: 5°C to 28°C (41°F to 82.4°F); altitude: 2134 m (7000 ft) to
3050 m (10000 ft).
– Server off: 5°C to 45°C (41°F to 113°F)
– Shipping: -40°C to 60°C (-40°F to 140°F)
v Humidity:
– Server on: 8% to 80%; maximum dew point: 21°C; maximum rate of
change: 5 °C/hr
– Server off: 8% to 80%; maximum dew point: 27°C
v Design to ASHRAE Class A3, ambient of 35°C to 40°C, with relaxed
support:
– Support cloud like workload with no performance degradation
acceptable (Turbo-Off)
– Under no circumstance, can any combination of worst case workload
and configuration result in system shutdown or design exposure at
40°C
v Particulate contamination:
Attention: Airborne particulates and reactive gases acting alone or in
combination with other environmental factors such as humidity or
temperature might pose a risk to the server. For information about the
limits for particulates and gases, see "Particulate contamination" on page
753.
v Input voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
v Input voltage high range:
– Minimum: 200 V ac
– Maximum: 240 V ac
v Sine-wave input (50 ~ 60 Hz) required
v Input voltage range automatically selected
v Input kilovolt-amperes (kVA) approximately:

Advertisement