816f011b-0701ffff • 816f0125-0b02ffff
2.
If the problem persists and there is no other CPU with the same error indication, replace the system board.
3.
(Trained technician only) Replace the system board (see Removing the system board and Replacing the system
board). (n = microprocessor number)
816f011b-0701ffff
The connector [PhysicalConnectorElementName] configuration error has been repaired. (Front
USB)
Explanation: This message is for the use case when an implementation has detected an Interconnect Configuration
was Repaired.
May also be shown as 816f011b0701ffff or 0x816f011b0701ffff
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0267
SNMP Trap ID: 50
Automatically notify Support: No
User response: No action; information only.
816f0125-0b01ffff
[ManagedElementName] detected as present. (PCI Riser 1)
Explanation: This message is for the use case when an implementation has detected a Managed Element is now
Present.
May also be shown as 816f01250b01ffff or 0x816f01250b01ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0390
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
816f0125-0b02ffff
[ManagedElementName] detected as present. (PCI Riser 2)
Explanation: This message is for the use case when an implementation has detected a Managed Element is now
Present.
May also be shown as 816f01250b02ffff or 0x816f01250b02ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0390
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
528
System x3650 M4 BD Type 5466: Installation and Service Guide