800b010a-1e85ffff • 800b0309-1301ffff
800b010a-1e85ffff
Redundancy Lost for [RedundancySetElementName] has asserted. (Cooling Zone 5)
Explanation: This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010a1e85ffff or 0x800b010a1e85ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Make sure that the connectors on fan n are not damaged.
2.
Make sure that the fan n connectors on the system board are not damaged.
3.
Make sure that the fans are correctly installed.
4.
Reseat the fans.
5.
Replace the fans. (n = fan number)
800b010c-2581ffff
Redundancy Lost for [RedundancySetElementName] has asserted. (Backup Memory)
Explanation: This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010c2581ffff or 0x800b010c2581ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 41
Automatically notify Support: No
User response:
1.
Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the failures.
2.
Re-enable mirroring in the Setup utility.
800b0309-1301ffff
Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for
[RedundancySetElementName] has asserted. (Power Resource)
Explanation: This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded
or Fully Redundant to Non-redundant:Sufficient.
May also be shown as 800b03091301ffff or 0x800b03091301ffff
Severity: Warning
Alert Category: Warning - Redundant Power Supply
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0806
SNMP Trap ID: 10
Automatically notify Support: No
User response:
1.
Non-redundant sufficient: Power load will be handled by remaining power supply, though the system may
throttle to avoid a power supply over-current condition.