Analog Source (Monitored Item) Selection - Mitsubishi FR-A800 Instruction Manual

Hide thumbs Also See for FR-A800:
Table of Contents

Advertisement

(A) Application parameters
Analog source (monitored item) selection
• Select the analog sources (monitored items) to be set to Pr.1027 to Pr.1034 from the table below.
Monitored item
1
Output frequency/speed
2
Output current
3
Output voltage
Frequency setting value/speed
5
setting
6
Running speed
7
Motor torque
8
Converter output voltage
9
Regenerative brake duty

Electronic thermal O/L relay load
10
factor
11
Output current peak value
Converter output voltage peak
12
value
13
Input power
14
Output power
17
Load meter
18
Motor excitation current
19
Position pulse
20
Cumulative energization time
22
Orientation status
23
Actual operation time
24
Motor load factor
32
Torque command
33
Torque current command
34
Motor output
35
Feedback pulse
40
PLC function user monitor 1
41
PLC function user monitor 2
42
PLC function user monitor 3
52
PID set point
53
PID measured value
54
PID deviation
61
Motor thermal load factor
62
Inverter thermal load factor
64
PTC thermistor resistance
67
PID measured value 2
87
Remote output value 1
88
Remote output value 2
89
Remote output value 3
90
Remote output value 4

"*" shows a monitored item with a high-speed sampling cycle.

"" shows that the display with a minus sign is available.

Indicates a criterion at 100% when the analog trigger is set.

Refer to Terminal FM, CA, AM Full-scale value

Monitoring is available only for standard models.

Rated motor frequency  120 / number of motor poles
550
PARAMETERS
















65535
65535
65535
65535




65535








Pr.561





(page
370).
Monitored item
91
PID manipulated variable
92
Second PID set point
93
Second PID measured value
94
Second PID deviation
95
Second PID measured value 2
96
Second PID manipulated variable
97
Dancer main speed setting
98
Control circuit temperature
201
*Output frequency
202
*U Phase Output Current
203
*V Phase Output Current
204
*W Phase Output Current
205
*Converter Output Voltage
206
*Output Current (all three phases)
207
*Excitation Current(A)
208
*Torque Current(A)
209
Terminal 2
210
Terminal 4
211
Terminal 1
212
*Excitation Current (%)
213
*Torque Current (%)
222
Position command
223
Position command (upper digits)
224
Current position
225
Current position (upper digits)
226
Droop pulse
227
Droop pulse (upper digits)
230
*Output Frequency (signed)
231
*Motor Speed
232
*Speed Command
235
*Torque Command
236
*Motor Torque
237
*Excitation Current Command
238
*Torque Current Command









Pr.84
ND rated
current
ND rated
current
ND rated
current
400 V/800 V
ND rated
current
ND rated
current
ND rated
current
100%
100%
100%
100%
100%
65535
65535
65535
65535
65535
65535
Pr.84


100%
100%
100%
100%