Forward/reverse rotation speed limit using analog input (Pr.1113="9999",
Pr.807="2")
• When performing speed limit by analog inputs to terminal 1, speed limit can be switched between forward and reverse
rotation by its voltage polarity.
• When Pr.868 Terminal 1 function assignment ="5", forward/reverse speed limit is enabled.
• If 0 to 10 V is input, forward rotation speed limit is applied. Reverse rotation speed limit at this time is the value of Pr.1
Maximum frequency.
• If -10 to 0 V is input, reverse rotation speed limit is applied. Forward rotation speed limit at this time is the value of Pr.1.
• Upper speed limit is the value of Pr.1 for both forward and reverse rotations.
When terminal 1 input is "-10 to 0V"
Speed
Torque controllable range
150
Speed
Pr.1
The forward rotation
speed limit
Terminal 1 input
(-10 to 0V)
Pr.7
The reverse
rotation speed
limit
Start signal
OFF
ON
NOTE
• To perform speed limit by using the terminal 1, calibrate the terminal 1. (Refer to
Torque control under Real sensorless vector control and vector control
Forward rotation
Pr.1
0
150
Output torque (%)
Terminal 1 input
Reverse rotation
Torque controllable range
Time
Pr.8
When terminal 1 input is "0 to 10V"
150
Torque controllable range
Speed
Terminal 1 input (0 to 10V)
The forward rotation speed
limit
Pr.1
The reverse rotation
speed limit
OFF
Start signal
page
Speed
Forward rotation
Terminal 1
input
0
150
Output
torque (%)
Pr.1
Reverse rotation
Torque controllable range
Pr.7
Pr.8
ON
415.)
PARAMETERS
Time
5
221

Hide quick links: