Setting the applied motor
• Refer to the following list and set the parameters according to the applied motor.
Pr.71 Pr.450
0
(Pr.71 initial
Standard motor (such as SF-JR)
value)
Constant-torque motor (SF-JRCA, etc.)
1
SF-V5RU (other than 1500 r/min series)
Standard motor (such as SF-JR)
2
―
Adjustable 5 points V/F (Refer to
Mitsubishi standard motor (SF-JR 4P 1.5
20
kW or lower)
Vector control dedicated motor
30
SF-V5RU (1500 r/min series)
SF-THY
40
Mitsubishi high-efficiency motor SF-HR
50
Mitsubishi constant-torque motor SF-HRCA
Mitsubishi high-performance energy-saving
70
motor SF-PR
330
IPM motor MM-CF
8090
IPM motor (other than MM-CF)
9090
SPM motor
3 (4)
Standard motor (such as SF-JR)
Constant-torque motor (SF-JRCA, etc.)
13 (14)
SF-V5RU (other than 1500 r/min series)
Mitsubishi standard motor (SF-JR 4P 1.5
23 (24)
kW or lower)
Vector control dedicated motor
33 (34)
SF-V5RU (1500 r/min series)
SF-THY
43 (44)
Mitsubishi high-efficiency motor SF-HR
53 (54)
Mitsubishi constant-torque motor SF-HRCA
Mitsubishi high-performance energy-saving
73 (74)
motor SF-PR
333 (334)
IPM motor MM-CF
8093 (8094)
IPM motor (other than MM-CF)
9093 (9094)
SPM motor
5
Standard motor
15
Constant-torque motor
6
Standard motor
16
Constant-torque motor
9999
―
(initial
No second applied motor
value)
The setting is available for FR-A820-00630(11K) or lower.
For the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
For the FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher.
The same operation is performed for the both settings.
Constant value range when
Motor
performing offline auto tuning
Pr.82(Pr.455) and Pr.859(Pr.860)
• 0 to 500 A, 9999 (0.01 A)
• 0 to 3600 A, 9999 (0.1 A)
Pr.90(Pr.458) and Pr.91(Pr.459)
• 0 to 50 Ω, 9999 (0.001 Ω)
• 0 to 400 mΩ, 9999 (0.01 mΩ)
Pr.92(Pr.460) and Pr.93(Pr.461)
page
603.)
(Induction motor)
• 0 to 6000 mH, 9999 (0.1 mH)
• 0 to 400 mH, 9999 (0.01 mH)
Pr.92(Pr.460) and Pr.93(Pr.461)
(PM motor)
• 0 to 500 mH, 9999 (0.01 mH)
• 0 to 50 mH, 9999 (0.001 mH)
Pr.94(Pr.462)
• 0 to 100%, 9999(0.1%)
• 0 to 100%, 9999(0.01%)
Pr.706(Pr.738)
• 0 to 5000 mV/(rad/s), 9999
(0.1 mV/(rad/s))
Pr.82(Pr.455), Pr.859(Pr.860),
Pr.90(Pr.458), Pr.91(Pr.459),
Pr.92(Pr.460), Pr.93(Pr.461),
Pr.94(Pr.462) and Pr.706(Pr.738)
• Internal data value 0 to 65534, 9999 (1)
The display increment can be changed
in Pr.684.
Star
connection
Delta
connection
(C) Motor constant parameters
Operational characteristic of
(increment)
Standard
Pr.82(Pr.455) and
Pr.859(Pr.860)
• 0 to 500 A, 9999 (0.01 A)
• 0 to 3600 A, 9999 (0.1 A)
Pr.90(Pr.458) and
Pr.91(Pr.459)
• 0 to 50 Ω, 9999 (0.001 Ω)
• 0 to 400 mΩ, 9999 (0.01
mΩ)
Pr.92(Pr.460) and
Pr.93(Pr.461)
• 0 to 50 Ω, 9999 (0.001 Ω)
• 0 to 3600 mΩ, 9999 (0.1
mΩ)
Pr.94(Pr.462)
• 0 to 500 Ω, 9999 (0.01 Ω)
• 0 to 100 Ω, 9999 (0.01 Ω)
the electronic thermal O/L
relay
Constant-
PM
torque
439
PARAMETERS
5