Mitsubishi FR-A800 Instruction Manual page 455

Hide thumbs Also See for FR-A800:
Table of Contents

Advertisement

(C) Motor constant parameters
Pr.
Name
463
Second motor auto tuning
C210
setting/status
458
Second motor constant (R1)
C220
460
Second motor constant (L1)
C222
/ d-axis inductance (Ld)
461
Second motor constant (L2)
C223
/ q-axis inductance (Lq)
Second motor torque
860
current/Rated PM motor
C226
current
738
Second motor induced
C230
voltage constant (phi f)
739
Second motor Ld decay
C231
ratio
740
Second motor Lq decay
C232
ratio
741
Second starting resistance
C282
tuning compensation
742
Second motor magnetic
C285
pole detection pulse width
746
Second motor protection
C233
current level

For FR-A820-00077(0.75K) or lower and FR-A840-00038(0.75K) or lower, it is set to 85% of the inverter rated current.

For the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.

For the FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher.

Differs according to the voltage class. (200 V/400 V)

The setting range and unit change according to the Pr.71 (Pr.450) setting.
POINT
POINT
• The settings are valid under the PM sensorless vector control.
• The offline auto tuning enables the operation with SPM motors and IPM motors other than MM-CF. (When a PM motor other
than the IPM motor MM-CF is used, always perform the offline auto tuning.)
• Tuning is enabled even when a load is connected to the motor.
• Reading/writing of the motor constants tuned by offline auto tuning are enabled. The offline auto tuning data (motor
constants) can be copied to another inverter with the operation panel.
• The offline auto tuning status can be monitored with the operation panel and the parameter unit.
454
PARAMETERS
Initial
Setting range
value
0, 101
1
0
11
0 to 50 Ω, 9999

9999
0 to 400 mΩ, 9999
0 to 500 mH, 9999
9999
0 to 50 mH, 9999
0 to 500 mH, 9999
9999
0 to 50 mH, 9999
0 to 500 A, 9999
9999
0 to 3600 A, 9999
0 to 5000 mV/(rad/s)
9999
9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 200%, 9999
0 to 6000 μs,
9999
10000 to 16000 μs, 9999
100 to 500%
9999
9999
No auto tuning for the second motor.
Performs offline auto tuning without
rotating the second motor. (motor other
than the IPM motor MM-CF)
Performs offline auto tuning without
rotating the motor (for IPM motor MM-
CF).

Tuning data of the second motor

(The value measured by offline auto

tuning is automatically set.)
9999: Uses the MM-CF constant for the

IPM motor MM-CF, and the inverter

internal data for a PM motor other than

MM-CF.

Set this parameter according to the PM

motor specifications.
Value calculated based on the tuning
data.
Tuning data of the second motor.
(The value measured by offline auto
9999: Uses the MM-CF constant for the
IPM motor MM-CF, and the inverter
internal data for a PM motor other than
MM-CF.
Set the maximum current (OCT) level of
the second motor.
Uses the MM-CF constant for the IPM
motor MM-CF, and 200% for a PM motor
other than MM-CF.
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents