Body I (Assembly Procedure); Lock Intermediate Lever - Pentax 67 II Service Manual

Hide thumbs Also See for 67 II:
Table of Contents

Advertisement

2.
Body I
(assembly
procedure)
2.1 Mirror box
and
hody II
l) Set
the
shutter curtain
to the
charge completion state
and
the mirror base
plate
(0-01)
to the released
state.
2) Apply G21
liberally
to C9 and
the
gear sections of related parts.
3) Fit
the
mirror box
into the body
while
paying attention to
the positions
of O-C20 and
O-E87.
At the
same
time,
temporarily
assemble C9 and
related parts.
(Do
not
attach with screws.)
4) Draw
the mirror box
to the Back cover key side and attach
screws and
washers
as shown
in the drawing.
Adjust: W31 should
be inserted
at
the
same thickness as
the
gap
between the body
and
the
axial
plate
(O-E67).
5)
Arrange the
seven
lead
wires
beneath the
body.
6) Attach C9
in the
order
D147,
CNMl.7 x3.0
and apply
Screw
lock.
Check: Check for smooth rotation of
the
gears.
7) Apply black
paint in
order
to prevent light leakage.
NB:
Ensure
that
the
paint does not
protrude.
2.2 Lock
intermediate
lever B (0 -C2G)
1)
Make it
hold the
S300 (magnet) and
move
O-E91.
2) Apply G21
to the lever
shaft.
3) O-C26, C92 (spring), CNL-Fl.4
x2.5
_
~
4)
Attach the
spring.
\..>
27340
.
~-
~
"--. . . . . . _ '
·
~'@
\
~
@-'cNs 2.0x7.0
' A 12
CD
'
'
®-cNS
2.ox?.o
I
~
CN$1.7x4.5
-CD
0147
®cNM1.7x3.0
<f'-
CNL-F14x2 5
C92. . . . . _
i
O-C26
nno