6.18 D59
(Magnet
plate), D23 (Magnet. plate retainer screw)
1) Insert
D59
into the Mirror box and
screw
tight with
CNL-D
l.7
x2.5 and
E9.l
2)
Adjust
:
Position of
S200
(H.c
lease
MG).
Loosen
S200
screws (TY-CNL-B
1.4
x4.0 x2),
push down in .::--- direction shown in drawing,
adjust
so that the armature
shaft comes
into
contact
with the long
hole
of
the
amrnture
and
comes
into
the
center of
the long
hole,
and
tighten TY-CNL-B 1.4 x4.0
x2.
E93
Center
-
Pushing dir11cliori
3)
Charge the
mirror
and
make
sure
that the
stopper
does not
come
loose.
The
stopper should come off when electricity(l.7V)
is apply to magnet.
4) Apply
Three Bond (1401C)
to TY-CNL-B 1.4 x4.0
x2.
6.19 D37 (FPC install plate)
1) Install D37 on the mirror box and
fix
with CNL-D
1.7 xl.6 and CNL-D 1.7
x2.5.
--
cNL-D1.7xt.6
6.20 D72
(Wind-end
SW fixed contact),
D73 (Wind-end SW moving contact)
(j)
Gap Wind-end
sw
l. Install D72 and D73 with 0-Dl in
the charged
state
and fix with
CNL-Dl.7
x2.5.
2.
At
the
mirror
charged
state.,
Check
:
CD
Wind-completion SW
gap.
0.5
mm
±-
0.1
mm
073
a
0
.5:!0.1mm
0
072
CNL -01 .7x2.5
®Tbe
mirror restoring lever
should
be
stopped
by contact
pressure of D72 and
D7'.I.
3. Pass