Hp Trusted Platform Module; Access Panel - HP ProLiant DL380 G7 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL380 G7:
Table of Contents

Advertisement

WARNING:
Do not disable the power cord grounding plug. The grounding plug is an important safety
feature.
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all
times.
Unplug the power cord from the power supply to disconnect power to the equipment.
Do not route the power cord where it can be walked on or pinched by items placed against it.
Pay particular attention to the plug, electrical outlet, and the point where the cord extends from
the server.
WARNING:
internal system components to cool before touching them.
CAUTION:
Operating the server in this manner results in improper airflow and improper cooling that can
lead to thermal damage.

HP Trusted Platform Module

The TPM is not a customer-removable part.
CAUTION:
the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM,
administrators should consider the system compromised and take appropriate measures to ensure
the integrity of the system data.
If you suspect a TPM board failure, leave the TPM installed and remove the system board. Contact an HP
authorized service provider for a replacement system board and TPM board.

Access panel

WARNING:
internal system components to cool before touching them.
CAUTION:
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
To remove the component:
Power down the server if performing a non-hot-plug installation or maintenance procedure
1.
down the
Extend the server from the rack (on page 27).
2.
Use the T-15 Torx screwdriver attached to the rear of the server to loosen the security screw on the hood
3.
latch.
Lift up on the hood latch handle, and then remove the access panel.
4.
To replace the component, reverse the removal procedure.
To reduce the risk of electric shock or damage to the equipment:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
Do not operate the server for long periods with the access panel open or removed.
Any attempt to remove an installed TPM from the system board breaks or disfigures
To reduce the risk of personal injury from hot surfaces, allow the drives and the
For proper cooling do not operate the server without the access panel, baffles,
server" on page 26).
Removal and replacement procedures 31
("Power

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents