To replace the component, reverse the removal procedure.

Hot-plug fan

The server supports variable fan speeds. The fans operate at minimum speed until a temperature change
requires a fan speed increase to cool the server.
The server shuts down in the following temperature-related scenarios:
At POST:
The BIOS suspends the server for 5 minutes if it detects a cautionary temperature level. If the
o
cautionary temperature level is still detected after 5 minutes, the BIOS performs an orderly shutdown
and enters Standby mode.
The BIOS performs an orderly shutdown if two or more fans have failed.
o
The server performs an immediate shutdown if it detects a critical temperature level.
o
IMPORTANT:
firmware or software actions.
In the operating system:
The Health Driver performs an orderly shutdown if it detects a cautionary temperature level. If the
o
server detects a critical temperature level before the orderly shutdown occurs, the server performs an
immediate shutdown. Additionally, the Health Driver performs an orderly shutdown if more than
one fan is failed or removed.
When Thermal Shutdown is disabled in RBSU, the server performs an immediate shutdown if it
o
detects a critical temperature level.
IMPORTANT:
firmware or software actions.
To remove the component:
Extend or remove the server from the rack
1.
server from the
Remove the access panel
2.
An immediate shutdown is a hardware-controlled function and it overrides any
An immediate shutdown is a hardware-controlled function and it overrides any
rack" on page 27).
("Access
panel" on page 31).
("Remove the server from the
Removal and replacement procedures 40
rack" on page 28,
"Extend the