Green LED
Flashing (2 Hz)
Alternating with
amber LED
On
Off
Hot-plug fans
CAUTION:
and 6 in a single-processor configuration.
The only two valid fan configurations are listed in the following table.
Configuration
1 processor
2 processors
For a single-processor configuration, four fans and two blanks are required in specific fan bays for
redundancy. A fan failure or missing fan causes all fans to spin at high speed. A second fan failure or missing
fan causes an orderly shutdown of the server.
Installing more than the required number of fans in a single-processor configuration is not a supported
configuration.
For a dual-processor configuration, six fans are required for redundancy. A fan failure or missing fan causes
all fans to spin at high speed. A second fan failure or missing fan causes an orderly shutdown of the server.
The server supports variable fan speeds. The fans operate at minimum speed until a temperature change
requires a fan speed increase to cool the server. The server shuts down during the following
temperature-related scenarios:
Amber LED
Interpretation
Flashing (2 Hz)
One of the following conditions exists:
Alternating with
•
The charging process has timed out.
green LED
•
The capacitor pack is not connected.
On
The flash code image failed to load.
Off
The flash code is corrupt.
To avoid damage to server components, fan blanks must be installed in fan bays 5
Fan bay 1 Fan bay 2 Fan bay 3
Fan
Fan
Fan
Fan
Fan bay 4 Fan bay 5 Fan bay 6
Fan
Fan
Fan
Fan
Fan blank
Fan blank
Fan
Fan
Component identification 103