HP ProLiant DL380 G7 Maintenance And Service Manual page 56

Hide thumbs Also See for ProLiant DL380 G7:
Table of Contents

Advertisement

CAUTION:
For proper cooling do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
Power down the server (on page 26).
1.
Extend or remove the server from the rack
2.
server from the
rack" on page 27).
Remove the access panel
3.
If any full-length expansion boards are installed, remove the full-length expansion board shipping
4.
bracket
("Full-length expansion board shipping
Remove the PCI riser cage
5.
Remove the expansion slot cover:
6.
To remove slot cover 1 or 4, push in on the retainer to release it, and then slide out the cover.
o
To remove slot covers 2 and 3, lift up on the latch, remove the latch, and then remove the cover.
o
("Remove the server from the
("Access
panel" on page 31).
bracket" on page 32).
("PCI riser
cage" on page 33).
rack" on page 28,
Removal and replacement procedures 56
"Extend the