Mantel Leg Clearances - Regency HZ54E Quick Start Manual

Table of Contents

Advertisement

MANTEL CLEARANCES
Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in
the diagram on the right.
Note: A non-combustible mantel may be
installed at a lower height if the framing
is made of metal studs covered with a
non-combustible board.
Note: Ensure the paint that is used on the mantel
and the facing is "High Quality" or the paint
may discolour.

MANTEL LEG CLEARANCES

Combustible mantel leg clearances as per diagram:
14
12
10
8
6
4
30
13" (330mm)
3 ½" (89mm)
1" (25mm)
20
30"
10
0
Top of
Fireplace
28-1/8"
Opening
To Unit
Base Legs
MANTEL LEG
Allowable mantel
leg projection
0
2
Combustible Material
Drywall
Metal Stud
(On Edge)
Non-combustible facing.
Must be supported
21"
using steel stud or
the framing kit
Standoff
20"
4"(102mm)
Non-Combustible
1.5" (38mm)
5-1/2" (140mm)
8" (203mm)
11" (279mm)
HZ54E-11 Gas Fireplace
|
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hz54e-ng11Hz54e-lp11

Table of Contents