Horizontal Terminations; Two (2) 90 O Elbows (Rigid Pipe 4" X 6 - 5/8"); Three (3) 90 - Regency Bellavista B36XTE Owners & Installation Manual

Hide thumbs Also See for Bellavista B36XTE:
Table of Contents

Advertisement

One 90
elbow = Two 45
o
Option
V
H + H1
A)
0' Min.
2' Max.
B)
1' Min.
3' Max.
C)
2' Min.
4' Max.
D)
3' Min.
5' Max.
E)
4' Min.
6' Max.
F)
5' Min.
7' Max.
G)
6' Min.
8' Max
No Vent Restrictor Installed
Lengths do not include elbow indicated.
Must use reducer # 946-606 and rigid pipe adaptor #770-994.
One 90
elbow = Two 45
o
Option
V
H
A)
0' Min.
1' Max. 1' Min.
B)
1' Min.
2' Max. 3' Min.
C)
2' Min.
2' Max. 5' Min.
D)
3' Min.
2' Max. 7' Min.
E)
4' Min.
3 Max. 9' Min.
F)
5' Min.
4' Max. 10' Min. 7' Max.
G)
6' Min.
5' Max. 11' Min. 8' Max.
H)
7' Min.
6' Max. 12' Min. 9' Max.
No Vent Restrictor Installed
Lengths do not include elbow indicated.
Must use reducer # 946-606 and rigid pipe adaptor #770-994.

HORIZONTAL TERMINATIONS

TWO (2) 90
H1
elbows.
o
W i t h t h e s e o p t i o n s ,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.
Please note minimum 1
foot between 90
elbows
o
is required.
HORIZONTAL TERMINATIONS

THREE (3) 90

ELBOWS (RIGID PIPE 4" X 6 - 5/8")
O
H1
elbows.
o
V + V1
H + H1
With these options,
2' Max.
max. total pipe length
is 30 feet with min. of
3' Max.
12 feet total vertical
4' Max.
and max. 9 feet total
5' Max.
horizontal.
6' Max.
Please note min. 1
foot between 90
elbows is required.
ELBOWS (RIGID PIPE 4" X 6 - 5/8")
O
V1
o
installation
H
V
Regency Bellavista™ B36XTE-10 Gas Fireplace
|
31
V
|
31

Advertisement

Table of Contents
loading

Table of Contents