Maintenance Instructions; Log Replacement; Bulb Replacement - Regency Bellavista B36XTE Owners & Installation Manual

Hide thumbs Also See for Bellavista B36XTE:
Table of Contents

Advertisement

maintenance
|
58
MAINTENANCE
INSTRUCTIONS
1) Always turn off the gas valve before cleaning.
For relighting, refer to lighting instructions. Keep
the burner and control compartment clean by
brushing and vacuuming at least once a year.
When cleaning the logs, use a soft clean
paint brush as the logs are fragile and easily
damaged.
2) Clean appliance and door with a damp cloth
(never when unit is hot). Never use an abrasive
cleaner. The glass should be cleaned with a
gas fireplace glass cleaner. The glass should
be cleaned when it starts looking cloudy.
3) The heater is finished in a heat resistant
paint and should only be refinished with heat
resistant paint. Regency
®
Paint - Metallic Black #6309.
4) Make a periodic check of burner for proper
position and condition. Visually check the
flame of the burner periodically, making sure
the flames are steady; not lifting or floating.
If there is a problem, call a qualified service
person.
5) The appliance and venting system must be
inspected before use, and at least annually,
by a qualified field service person, to ensure
that the flow of combustion and ventilation air
is not obstructed.
Note: Never operate the appliance without the
glass properly secured in place.
6) Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to
replace any part of the control system and any
gas control which has been under water.
7) In the event this appliance has been serviced
check that the vent-air system has been
properly resealed & reinstalled in accordance
with the manufacturer's instructions.
8) Verify operation after servicing.
General Vent Maintenance
Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:
1) Check the Venting System for corrosion in areas
that are exposed to the elements. These will
appear as rust spots or streaks, and in extreme
cases, holes. These components should be
replaced immediately.
2) Remove the Cap, and shine a flashlight down
the Vent. Remove any bird nests, or other
foreign material.
3) Check for evidences of excessive condensation,
such as water droplets forming in the inner
58 |
Regency Bellavista™ B36XTE-10 Gas Fireplace
liner, and subsequently dripping out the joints,
Continuous condensation can cause corrosion
of caps, pipe, and fittings. It may be caused
by having excessive lateral runs, too many
elbows, and exterior portions of the system
being exposed to cold weather.
4) Inspect joints, to verify that no pipe sections or
fittings have been disturbed, and consequently
loosened. Also check mechanical supports
such as Wall Straps, or plumbers' tape for
rigidity.

LOG REPLACEMENT

The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door and carefully remove the logs.
(The pilot light generates enough heat to burn
uses StoveBright
someone.) If for any reason a log should need
replacement, you must use the proper replacement
log. The position of these logs must be as shown
in the Diagrams under Log Installation.
Note: Improper positioning of logs may create
carbon build-up and will severely alter
the unit's performance which is not
covered under warranty.
If the glass gasket requires replacement use a
tadpole glass gasket (Part # 936-155).
GLASS GASKET
DOOR GLASS
Your Regency
fireplace is supplied with high
®
temperature 5mm-Ceramic glass. If your glass
requires cleaning, we recommend using an
approved glass cleaner available at all authorized
dealers. Do not use abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all
product warranties.
* Care must be taken to avoid breakage of
the glass.
* Do not strike or abuse the glass.
* Do not operate this fireplace without the
glass front or with a cracked or broken
glass front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panels should be
done by a licensed or qualified service per
son.
GLASS REPLACEMENT
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only. Replacement glass (Part
#940-357/P) is shipped already installed into
the door frame. Reinstall as per Glass Door
Installation in the "Glass Door Removal" section.

BULB REPLACEMENT

1) Follow steps 1- 4 on page 53.
2) Remove 2 screws to remove light diffuser
plus gasket.
3) Replace the bulb - do not touch bulb with
bare hands, use gloves or bulb packaging
to protect bulb.
4) Reverse steps.

Advertisement

Table of Contents
loading

Table of Contents