installation
|
26
These venting systems, in combination with the B36XTE Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by
Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations Diagram in "Exterior Vent
Termination Locations" section.
Regency
Direct Vent (Flex) System 4 foot Termination Kit (Part# 946-615) includes all the parts needed to install the B36XTE with a either
®
a top or rear vent.
Note: If top venting this unit, the 5" x 8" venting may only be used if venting to the minimum of 42-1/8" to centerline.
No other application is approved.
FPI Kit #
Length Contains:
#946-615
4 Feet
1) 8" dia. flexible liner (4 ft. length)
2) 5" dia. flexible liner (4 ft. length)
3) spring spacers (4)
4) thimble
5) AstroCapXL termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point,
Stainless Steel (4)
10) vinyl siding standoff
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex installations.
3) Regency
Direct Vent System (Flex) is only approved for horizontal terminations.
®
Note: If longer runs are required - rigid pipe must be used.
26 |
Regency Bellavista™ B36XTE-10 Gas Fireplace

HORIZONTAL TERMINATIONS

1)
8" flexible liner (Kit length)
2)
5" flexible liner (Kit length)
3)
spring spacers
4)
thimble
5)
AstroCap termination cap
6)
screws
7)
tube of Mill Pac
8)
plated screws
9)
S.S. screws #8 x 1-1/2" drill point
10) vinyl siding standoff

FLEX VENT 5" X 8"