Clearances - Regency Bellavista B36XTE Owners & Installation Manual

Hide thumbs Also See for Bellavista B36XTE:
Table of Contents

Advertisement

installation
|
10
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance
that this fireplace and vent system be installed only in accordance with these instructions.
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
10 |
Regency Bellavista™ B36XTE-10 Gas Fireplace
B36XTE Clearance Requirements
Clearance:
A: Mantel Height (min.)
B: Sidewall
12" (304mm) one side
C: Ceiling
36-3/4" (933mm)
D: Mantel Depth (max.)
E: Alcove Width
F: Alcove Depth
Notes:

CLEARANCES

if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
Dimension
Measured From:
13" (330mm)
Top of Fireplace Opening
Side of Fireplace Opening
only
Top of Fireplace Opening
12" (304mm)
21 " (533mm) from
Top of Fireplace Opening
84" (2134mm)
Wall to Wall (Minimum)
36" (914mm)
Front to Back Wall (Maximum)
0"
No Hearth Required
WARNING
Fire hazard is an extreme risk
E
F
Alcove
Minimum Vent Clearances
to Combustibles
Horizontal Top
2" (51mm)
Horizontal Side
1-1/2 " (38mm)
Horizontal Bottom
1-1/2" (38mm)
Vertical Vent
1-1/2" (38mm)

Advertisement

Table of Contents
loading

Table of Contents