WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
918-759
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Gas Fireplace
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
B36X
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
Owners &
Installation Manual
MODEL: B36X
Medium DV Gas Fireplace
02/05/09

Advertisement

Table of Contents
loading

Summary of Contents for Regency Bellavista B36X

  • Page 1 Homeowner: Please keep these instructions for future reference. Owners & B36X Installation Manual MODEL: B36X Medium DV Gas Fireplace FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appliance...
  • Page 2: Manufactured Mobile Home Requirements

    . The Bellavista™ ® B36X has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The Bellavista™ B36X has been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
  • Page 3: Table Of Contents

    Venting Arrangement - Vertical Terminations ...31 Unit Installation with Horizontal Termination ...33 Unit installation with Vertical Termination ...34 Gas Line Installation ...34 Regency Bellavista™ B36X Gas Fireplace Pilot Adjustment ...35 High Elevation ...35 Gas Pipe Pressure Testing ...35 S.I.T. Valve Description ...35 Aeration Adjustment ...36...
  • Page 4: Safety Label

    SAFETY LABEL This is a copy of the label that accompanies each Bellavista™ B36X Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being ® improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
  • Page 5: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency Bellavista™ B36X Gas Fireplace...
  • Page 6: Dimensions

    DIMENSIONS UNIT DIMENSIONS 33” (838mm) 35-1/4” (895mm) 30-3/8” (762mm) 39-1/16” (992mm) 21”(533mm) 37-1/2” (953mm) 1”(25.4mm) 36” (914mm) 33-1/16” (840mm) 35-1/4” (895mm) 26-1/2” (673mm) 17-5/16” (440mm) 19-5/16” (490mm) 20-1/4” (514mm) Regency Bellavista™ B36X Gas Fireplace...
  • Page 7: Installation

    IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The Bellavista™ B36X Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation.
  • Page 8: Installation Checklist

    Remote (millivolt thermostat system). Some areas may have further requirements, check local codes before installation. 5) The B36X Gas Fireplace are approved for alcove installations, see "Clearances" section for details. 6) We recommend that you plan your installation...
  • Page 9: Clearances

    84" (2134mm) F: Alcove Depth 36" (914mm) Notes: Regency Bellavista™ B36X Gas Fireplace CLEARANCES if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fi replace and vent system be installed only in accordance with these instructions.
  • Page 10: Mantel Leg Clearances

    11" 6-1/2" (368mm) (279mm) (165mm) MANTEL LEG CLEARANCES 12” Side Wall (Measured from side of Fireplace Opening) 2" 5" Allowable mantel leg projection. Combustible 7” Top Header 1" Standoff Top of Side View Fireplace Opening Regency Bellavista™ B36X Gas Fireplace...
  • Page 11: Framing

    R (Rear Vent) R (Top Vent) S (Rear Vent) S (Top Vent) Note: If installing the unit into a corner and rear venting - use AstroCapXL 946-623/P to obtain closest clearance. Regency Bellavista™ B36X Gas Fireplace FRAMING Description Framing Width Framing Height...
  • Page 12: Finishing

    Diagram 3 Full Screen Door Diagram 4 1" Note: There is a 1" air space between the unit and full screen door which must not be covered. Regency Bellavista™ B36X Gas Fireplace 3/4" Finishing material - thicker than 1-1/4"...
  • Page 13: Unit Assembly Prior To Installation

    Use hole positions A, B, or C depending on your facing depth. Top Facing Support Top Facing Support is reversed for “C” hole position Regency Bellavista™ B36X Gas Fireplace BEFORE YOU START Screw Facing Material Position Depth 1/2" / 13mm 7/8"...
  • Page 14: Top Flue Collar Installation

    4) From the inside of the fi rebox, remove the exhaust assembly by removing the 8 - 1/4" x 1/2" screws. See Diagram 4. Intake Collar Plate Intake Collar Assembly w/gasket w/gasket Diagram 1 Diagram 4 Regency Bellavista™ B36X Gas Fireplace...
  • Page 15: Venting Introduction

    10) From inside the fi rebox, re-install the baffl e plate and heat defl ector - reverse steps 2 & 3. The B36X uses the "balanced fl ue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the...
  • Page 16: Exterior Vent Termination Requirements

    3 feet (91cm) above - if within 10 feet (3m) horizontally Canada 12"(30cm) 12"(30cm) 12"(30cm) 9" (23cm) 24"(60cm) 24"(60cm) 12"(30cm) 12"(30cm) 13"(33cm) 13"(33cm) 13"(33cm) 13"(33cm) 6"(15cm) 6"(15cm) 6"(15cm) 6"(15cm) 36"(90cm) 36"(90cm) 12"(30cm) 9" (23cm) 72"(1.8m) 36"(90cm) ┼ 84"(2.1m) 12"(30cm) ‡ Regency Bellavista™ B36X Gas Fireplace...
  • Page 17: Approved Venting Confi Gurations

    INSTALLATION APPROVED VENTING CONFIGURATIONS HORIZONTAL & VERTICAL TERMINATIONS Regency Bellavista™ B36X Gas Fireplace...
  • Page 18 This application is NOT approved Various applications Rigid Pipe Adaptor 770-994 See manual for details 946-606 Vent Reducer Not Approved This application is NOT approved Not Approved Not Approved Not Approved Not Approved Not Approved Not Approved Not Approved Regency Bellavista™ B36X Gas Fireplace...
  • Page 19: Rigid Pipe Cross Reference Chart

    RIGID PIPE CROSS REFERENCE CHART 4" X 6-5/8" (MUST USE VENT REDUCER # 946-606 AND RIGID PIPE ADAPTOR #770-994) Components from different Manufacturers may not be mixed. Not all Rigid Pipe components are available directly from FPI. Regency Bellavista™ B36X Gas Fireplace...
  • Page 20 INSTALLATION Regency Bellavista™ B36X Gas Fireplace...
  • Page 21: 5" X 8

    INSTALLATION RIGID PIPE CROSS REFERENCE CHART 5" X 8" Components from different Manufacturers may not be mixed. Not all Rigid Pipe components are available directly from FPI. Regency Bellavista™ B36X Gas Fireplace...
  • Page 22 INSTALLATION Regency Bellavista™ B36X Gas Fireplace...
  • Page 23: Horizontal Terminations

    REGENCY These venting systems, in combination with the B36X Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Locations"...
  • Page 24: Rigid Pipe Venting Arrangements (5" X 8")

    Rigid Pipe Adaptor The diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system. A vent guard should be used whenever the termination is lower than the specifi ed minimum or as per local codes.
  • Page 25: Rigid Pipe Venting Systems

    FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent American Metal Products, Security Secure Vent Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency Bellavista™ B36X Gas Fireplace RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations...
  • Page 26: Horizontal 5" X 8" Rigid Rear Vent Kit

    Across the face of the unit, wall to wall Standoff Inside corner to front face of the unit (Optional) Astrocap Wall Thimble Placement of the unit into the corner 4" 55-3/4" 78-1/4" 39-1/8" 26-1/2” (673mm) Regency Bellavista™ B36X Gas Fireplace...
  • Page 27: Venting Arrangements

    Rigid Pipe Venting Systems for Propane and Natural Gas. Two 45 Note: The Regency Direct Flex Kits (946-515 and 946-516) cannot be used in conjunction with the vent reducer and rigid pipe adaptor. Only rigid pipe may be used when 4" x 6-5/8" is ever used.
  • Page 28: Venting Arrangements Horizontal Termination

    Horizontal vent must be supported every 3 feet. • Firestops are required at each fl oor level and whenever passing through a wall. • A wall thimble is mandatory for all horizontal terminations due to high temperatures. ELBOWS Regency Bellavista™ B36X Gas Fireplace elbow).
  • Page 29: Vertical Venting With Three (3) 90

    8' Max. 10' Min. Vent Restrictor Set at 2" Opening Lengths do not include elbow indicated. Must use reducer # 946-606 and rigid pipe adaptor #770-994 Regency Bellavista™ B36X Gas Fireplace (RIGID PIPE 4" X 6 - 5/8") elbows. With these options, max.
  • Page 30: Vertical Termination With Co-Linear Flex System

    Reducer #946-606 (4 x 6-5/8 venting) Rigid Pipe Adapter 90 Degree # 770-994 Co-linear DV Cap # 946-529 Flex Liner Flue Elbow Inner Pipe Adapter with Kit# 946-563 Regency Bellavista™ B36X Gas Fireplace Air Intake Co-Linear Flex Adapter with Kit# 946-563...
  • Page 31: Venting Arrangement - Vertical Terminations

    # 946-606 & 2” Open #770-994 Rigid Pipe Adaptor Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. Regency Bellavista™ B36X Gas Fireplace CO-LINEAR FLEX SYSTEM INTO MASONRY FIREPLACES Restrictor 1” Open Use Reducer # 946-606 &...
  • Page 32 1-1/4 inches (32mm). Secure the connection between the vent pipe and the vent cap. 10) Install wall thimble in the center of the 11" (279mm) square and attach with wood screws (Diagram 7). Diagram 7 Regency Bellavista™ B36X Gas Fireplace...
  • Page 33: Unit Installation With Horizontal Termination

    4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are Regency Bellavista™ B36X Gas Fireplace on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls.
  • Page 34: Unit Installation With Vertical Termination

    Flare nuts for copper lines and fl ex connectors are usually considered to meet this requirement. Important: Always check for gas leaks with a soap and water solution or gas leak detector. Do not use open fl ame for leak testing. Regency Bellavista™ B36X Gas Fireplace...
  • Page 35: Pilot Adjustment

    5) Outlet Pressure Tap 6) Inlet Pressure Tap 7) Pilot Outlet 8) Main Gas Outlet 9) Alternative TC Connection Point Regency Bellavista™ B36X Gas Fireplace B36X -NG System Data Conversion Kit# 556-969 For 0 to 4500 feet altitude Burner Inlet Orifi ce Sizes: Max.
  • Page 36: Aeration Adjustment

    Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty. Optional Fan # 576-917 Ground Green Ground Black Minimum Convection Rotary Speed Air Temp. Switch Control "S.I.T" Valve (Optional) Regency Bellavista™ B36X Gas Fireplace...
  • Page 37: Wiring Diagram For Gtmf Remote

    #8 Ground Lug (for mobile home) Lockwasher ground wire Burner ON White Black WIRING DIAGRAM FOR GTMF REMOTE Regency Bellavista™ B36X Gas Fireplace Units and Units Equipped with DC Spark Boxes* Neutral Live 120V AC 60 Hz Pilot Assembly DC Spark...
  • Page 38: Vent Restrictor, Baffl E & Heat Defl Ector Installation

    6) From inside the fi rebox, install the top heat defl ector with 2 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not over tighten. Diagram 4 Heat Defl ector Regency Bellavista™ B36X Gas Fireplace...
  • Page 39: Conversion From Ng To Lp

    CONVERSION KIT# 556-969 FROM NG TO LP for B36X using SIT 820 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Each Kit contains one LP Conversion Kit # 556-969 Conversion Kit Contains: Qty.
  • Page 40 # decal. Also check that the pilot and main burner injectors are appropriate for 22) Replace yellow "NG" label with red "LPG" label. Fig.3 Fig.4 LPG Configuration Fig. 6 WARNING! the gas type. Regency Bellavista™ B36X Gas Fireplace...
  • Page 41: Dc Sparker Installation

    Wire 26) Connect the DC spark generator wires to the SIT Valve. Secure with a phillips head screw as shown below. Regency Bellavista™ B36X Gas Fireplace DC SPARKER INSTALLATION 27) Plug the DC spark generator wires to the DC Sparker.
  • Page 42: Brick Panel Installation

    6) Slide top brick panel under left and back brick panel, use care not to damage panel. 7) Right brick panel is installed last, follow the same procedure as for left panel (see step 5). 8) Reinstall top heat defl ector (reverse Step 3). Final Brick Panel Installation Regency Bellavista™ B36X Gas Fireplace...
  • Page 43: Optional Stainless Steel / Black Enamel

    Diagram 4. Slide slots of top panel into position under loosened screws, retighten the screws. Slots on Top Panel Regency Bellavista™ B36X Gas Fireplace PANEL INSTALLATION • Black Enamel panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time.
  • Page 44 1 screw (see inset B). Tighten the screw. Diagram 7 5) Repeat step 4 for left side panel. 6) Reverse step 1. LEFT Diagram 1 Diagram 2 Diagram 3 Fold Diagram 5 Diagram 6 Final Installation Regency Bellavista™ B36X Gas Fireplace...
  • Page 45: Log Set Installation

    1) Carefully remove the logs from the packaging and unwrap them. The logs are fragile, handle with care - do not force into position. Regency Bellavista™ B36X Gas Fireplace LOG SET INSTALLATION 2) Spread vermiculite along the base of the fi rebox.
  • Page 46 7) Position Log D across the cutouts in Logs A and B with the notch on the left side of the log fi tting into the 2nd grate tab. 2nd Grate Tab 5th Grate Tab Regency Bellavista™ B36X Gas Fireplace...
  • Page 47 8) Place the bottom left front edge of Log E against the rear bracket on the burner tray and rest the log on the notch of Log D. Notch in log D Regency Bellavista™ B36X Gas Fireplace Lava Rocks 9) Place the lava rocks on the front of the burner tray in the places shown in the photo.
  • Page 48: Optional Wall Thermostat

    12 Ft. 22 GA. 9 Ft. Optional REMOTE CONTROL Regency offers 3 different remote control options which are Profl ame GT, GTM and GTMF models. See next page of all available features of each version. Use the Regency Remote Control Kit approved ®...
  • Page 49 INSTALLATION Note: Regency Profl ame wall switches are white (not black as shown). Regency Bellavista™ B36X Gas Fireplace...
  • Page 50: Fan Installation

    IMPORTANT: These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming out the fan blades and housing using a soft brush nozzle. Regency Bellavista™ B36X Gas Fireplace...
  • Page 51: Flush Glass Door Installation

    2) Lower the fl ush door, then hook the 2 adjustable tension latches - close the latches to secure the fl ush door(See Diagram 2). Adjustable Tension Latch location Diagram 2 Note: To remove Flush Glass door reverse Steps 1 and 2. Regency Bellavista™ B36X Gas Fireplace...
  • Page 52: Optional Finishing Trim Installation

    Tabs on Louver/Flush Panel Bracket on unit for upper Louver/Flush Panel Edge of Unit Bracket on unit for lower Louver/Flush Panel Finishing Trim Top Finishing Trim Side Installation of upper Louver/Flush Panel Installation of lower Louver/Flush Panel Regency Bellavista™ B36X Gas Fireplace...
  • Page 53: Full Screen Arch Door And Frame Installation

    3/4" from the unit to accommodate fi nishing materials. See Diagram 2 Diagram 2 Regency Bellavista™ B36X Gas Fireplace 5) Install bottom mesh door . a) Locate tabs on bottom mesh door. b) Locate bracket on lower fl oor of unit.
  • Page 54: Operating Instructions

    Unit Body/Firebox: Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process. Regency Bellavista™ B36X Gas Fireplace...
  • Page 55: Copy Of Lighting Plate Instructions

    OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS Regency Bellavista™ B36X Gas Fireplace...
  • Page 56: Maintenance Instructions

    Regency dealer only. Replacement glass (Part # 940-358/P) is shipped already installed into the door frame. Reinstall as per Glass Door Installation in the "Glass Door Removal" section. Regency Bellavista™ B36X Gas Fireplace...
  • Page 57: Removing Valve

    7) Remove the 2 screws securing the rear log tray and lift out. Diagram 3 Diagram 3 Regency Bellavista™ B36X Gas Fireplace 8) Disconnect the inlet gas line. (see Diagram 4) Diagram 4 9) Disconnect the wall switch wires from the valve.
  • Page 58: Parts List

    946-005 Wall Adaptor Plate - White 946-002 Round to Oval Adaptor 946-001 Oval Duct Adaptor 946-007 Angle Bracket 946-517/P Fan Assembly - Heat Wave 946-004 Junction Box 918-759 Manual Not available as a replacement part. Regency Bellavista™ B36X Gas Fireplace...
  • Page 59 HEAT WAVE DUCT KIT HEAT WAVE DUCT KIT Regency Bellavista™ B36X Gas Fireplace MAIN ASSEMBLY FAN SWITCH ASSEMBLY FAN SWITCH ASSEMBLY PARTS LIST...
  • Page 60: Burner Assembly

    Valve NG/LP SIT High/Low 820 Valve Tray - B36X BURNER ASSEMBLY Part # 556-574/P 556-576/P 10) 910-038 910-039 910-386 910-341 Description Valve Assembly - NG Valve Assembly - LP Pilot Assembly - NG Pilot Assembly - LP Thermocouple Thermopile Regency Bellavista™ B36X Gas Fireplace...
  • Page 61 NOTES Regency Bellavista™ B36X Gas Fireplace...
  • Page 62 NOTES Regency Bellavista™ B36X Gas Fireplace...
  • Page 63: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect. The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency unauthorized service persons or dealers.
  • Page 64: The Warranty: Limited Lifetime

    ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency Bellavista is a trademark of FPI Fireplace Products International Ltd. © Copyright 2009, FPI Fireplace Products International Ltd. All rights reserved. http://www.regency-fi re.com online at ® Printed in Canada...