Regency Bellavista B36XTE Owners & Installation Manual

Medium dv gas fireplace
Hide thumbs Also See for Bellavista B36XTE:
Table of Contents

Advertisement

Bellavista ® B36XTE
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach you gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
919-390a
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Gas Fireplace
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
MODEL: B36XTE-10
Medium DV Gas Fireplace
Bellavista B36XT Video
www.regency-fire.com
10.28.15

Advertisement

Table of Contents
loading

Summary of Contents for Regency Bellavista B36XTE

  • Page 1 Installation Manual Gas Fireplace MODEL: B36XTE-10 Medium DV Gas Fireplace Bellavista B36XT Video www.regency-fire.com WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The Bellavista™ B36XTE has been designed to provide ® you with all the warmth and charm of a wood fireplace at the flick of a switch. The Bellavista™ B36XTE has been approved by Warnock Hersey/Intertek for both safety and efficiency.
  • Page 3: Manufactured Mobile Home Requirements

    MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: VENTED ® GAS FIREPLACE HEATERS ANSI Z21.88-2014 / CSA 2.33-2014 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN / CGA 2.17-M91.
  • Page 4: Table Of Contents

    table of contents Copy of Safety Decal .............5 Horizontal terminations ..........35 MA Code - CO Detector..........6 Three (3) 90 Elbows (Rigid Pipe 4" x 6 - 5/8") ....35 Unit Dimensions ............7 venting arrangements For Vertical TerminationS .36 Unit Dimensions with Vignette Finishing Trim ....8 Rigid pipe 4"...
  • Page 5: Copy Of Safety Decal

    This is a copy of the label that accompanies each Bellavista™ B36XTE Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, ®...
  • Page 6: Ma Code - Co Detector

    requirements MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 7: Unit Dimensions

    dimensions UNIT DIMENSIONS WITH VIGNETTE ONLY Bellavista® B36XTE-10 Gas Fireplace...
  • Page 8: Unit Dimensions With Vignette Finishing Trim

    dimensions UNIT DIMENSIONS WITH VIGNETTE AND VIGNETTE FINISHING TRIM UNIT DIMENSIONS WITH OPTIONAL FLUSH PANELS AND SAFETY SCREEN Bellavista® B36XTE-10 Gas Fireplace...
  • Page 9: Important Message

    installation IMPORTANT MESSAGE 3) See general construction and assembly YOUNG CHILDREN SHOULD BE CARE- instructions. The appliance and vent should SAVE THESE FULLY SUPERVISED WHEN THEY ARE be enclosed. INSTRUCTIONS IN THE SAME AREA AS THE APPLI- 4) This appliance must be connected to the ANCE.
  • Page 10: Installation Checklist

    installation INSTALLATION CHECKLIST This includes: 4) This appliance is Listed for bedroom installations using the standard Remote 1) Clocking the appliance to ensure the correct (millivolt thermostat system). Some areas 1) Locate appliance firing rate (rate noted on label 31,000 Btu/h, may have further requirements, check local a) Room location (Refer to "Locating Your after burning appliance for 15 minutes.
  • Page 11: Clearances

    installation CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. WARNING Caution Requirements Fire hazard is an extreme risk...
  • Page 12: Combustible Mantel Clearances

    installation COMBUSTIBLE MANTEL CLEARANCES Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: Mantel starts at *1" deep and ends at *12" deep. **For Vignette with Vignette Finishing Trim flush finish, all materials (framing & finishing) below the mantel and the width of the Vignette finishing trim, (37-3/4") must be non-combustible if a lower mantel is desired.
  • Page 13: Mantel Leg Clearances

    installation MANTEL LEG CLEARANCES 12 Side Wall (Measured from side of Fireplace Opening) 6.5" Allowable mantel leg projection. FRAMING 1) Determine the total thickness of facing material (e.g. non combustible plus ceramic tiles) to allow the finished surface to be flush with the front of the unit. Total facing thickness can vary from 1/2"...
  • Page 14: Framing

    installation FRAMING WITH VIGNETTE (NO FINISHING TRIM)OR WITH FLUSH PANELS AND SAFETY SCREEN - SEE NEXT PAGE FOR FRAMING FOR VIGNETTE AND VIGNETTE TRIM FINISHED FLUSH Framing Dimensions Description B36XTE Framing Width 40-5/8"(1032mm) Framing Height 42" (1067mm) O (Rear Vent) Framing Depth - Rear Vent 20-3/4"...
  • Page 15: Framing With Vignette (No Finishing Trim)Or With Flush Panels And Safety Screen

    installation FRAMING WITH VIGNETTE AND VIGNETTE TRIM FINISHED FLUSH Framing Dimensions Description B36XTE Framing Width 42-1/4"(1073mm) Framing Height 42" (1067mm) O (Rear Vent) Framing Depth - Rear Vent 22-1/8" (559mm) O (Top Vent) Framing Depth - Top Vent 21-7/8" (553 mm) P (Top Vent) Corner Facing Wall Width 51 - 5/16"...
  • Page 16 installation NON- COMBUSTIBLE REQUIREMENTS: Vignette (no Finishing Trim) or with Flush Panels and Vignette + Vignette Finishing Trim Flush Finished Safety Screen Diagram 1 Diagram 2 16 | Bellavista® B36XTE-10 Gas Fireplace...
  • Page 17: Wall Mount On / Off Switch And Remote Receiver Installation

    installation WALL MOUNT ON / OFF SWITCH AND REMOTE RECEIVER INSTALLATION REQUIRED FOR ALL INSTALLATIONS - INCLUDING PROFLAME REMOTE CONTROLS IMPORTANT INSTALLATION NOTE: The Receiver must be placed inside the supplied (Low Voltage) junction type wall box and installed into the wall only. DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE.
  • Page 18: Finishing

    installation FINISHING IMPORTANT FINISHING DETAIL NOTE: Before placing unit into final position - it is important to know the total Non-combustible thickness / height of finished hearth (tile, carpet, etc.) The base of the Material fireplace should be level or higher than the finished hearth height. J-style Trim or metal corner bead may be used to finish these...
  • Page 19: Top Facing Support

    Nail4.eps Top Facing Support Screw holes is reversed for Side installation for C hole position Nailing Strip Top Facing Support is reversed for C hole position TOP FACING SUPPORT (IF NOT USING VIGNETTE FINISHING TRIM) SIDE NAILING STRIPS Determine the total thickness of facing material (e.g. non combustible, drywall or wood plus The side nailing strips come attached to the unit.
  • Page 20: Conversion To Top Vent

    installation CONVERSION TO TOP VENT Note: This conversion must be done prior to the unit being placed in position. The unit comes equipped as a rear vent unit. These instructions are to be used, only if the unit is going to be top vented. Top Collar Assembly Kit Exhaust Assembly Intake Cover Plate...
  • Page 21 installation 5) From the outside rear of the firebox, remove the intake collar assembly. Remove the 4 - 1/4" x 1/2" screws. See Diagram 5. Diagram 9 Exhaust Assembly Intake Collar Assembly 9) From the outside top of the firebox, install the intake collar assembly. Secure with 4 - 1/4"...
  • Page 22: Vent Restrictor, Baffle & Heat Deflector Installation

    installation VENT RESTRICTOR, BAFFLE & HEAT DEFLECTOR INSTALLATION NOTE: THE VENT RESTRICTOR & BAFFLE MUST BE INSTALLED PRIOR TO OPTIONAL PANEL INSTALLATION. 1) Determine the venting configuration. 2) Remove top heat deflector and baffle plate (reverse of steps 5 & 6). 3) Go to venting arrangements section (in the manual) to determine if a vent restrictor setting is required.
  • Page 23: Exterior Vent Termination Requirements

    installation EXTERIOR VENT TERMINATION REQUIREMENTS Minimum Clearance Requirements Canada Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) Clearance to window or door that may be opened 12"(30cm) 9" (23cm) Clearance to permanently closed window Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) 24"(60cm) 24"(60cm) from the center line of the terminal (check with the local code)
  • Page 24: 4" X 6-5/8" Rigid Pipe

    Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF TM-4CS Trim Plate-Black 4DT-TP 4DFPB 4DcP SV4LA TM-4TP 24 | Bellavista® B36XTE-10 Gas Fireplace Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
  • Page 25 Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
  • Page 26: 5" X 8" Rigid Pipe

    - N/A from FPI Firestop Spacer 58DVA-FS 5DT-FS 5DFS TM-5LS Trim Plate-Black 58DAV-WFS 5DT-TP 5DCP TM-5TP 26 | Bellavista® B36XTE-10 Gas Fireplace Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
  • Page 27 Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. 48” (1219mm) 38-1/4” (972mm) 47-7/8” (1216mm) Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com Bellavista® B36XTE-10 Gas Fireplace...
  • Page 28: Astrocap Xl & Rigid Rear Vent Kit For Corner Installations

    installation B36X/XT HORIZONTAL TERMINATIONS ASTROCAP XL & RIGID REAR VENT KIT FOR CORNER INSTALLATIONS HORIZONTAL 5” X 8” RIGID REAR VENT KIT RIGID PIPE 5" X 8" - WHEN USING VIGNETTE FINISHING TRIM SEE NEXT PAGE FOR CORNER INSTALLATIONS Designed for a minimum vent configuration when using a rear vent application with a horizontal termination in a corner installation.
  • Page 29: Horizontal 5" X 8" Rigid Rear Vent Kit

    installation HORIZONTAL 5” X 8” RIGID REAR VENT KIT ASTROCAP XL & RIGID REAR VENT KIT FOR CORNER INSTALLATIONS RIGID PIPE 5" X 8" - WHEN IN- STALLED WITH VIGNETTE AND VIGNETTE FINISHING TRIM - FINISHED FLUSH Designed for a minimum vent configuration when using a rear vent application with a horizontal termination in a corner installation.
  • Page 30: Venting Arrangements For Horizontal Terminations

    FLEX VENT OR RIGID PIPE 5" X 8" The Diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system. A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
  • Page 31: Horizontal Terminations

    10) vinyl siding standoff Notes: 1) Liner sections should be continuous without any joints or seams. 2) Only Flex pipe purchased from Regency may be used for Flex installations. 3) Regency Direct Vent System (Flex) is only approved for horizontal terminations.
  • Page 32: Rigid Pipe 5" X 8

    installation HORIZONTAL TERMINATIONS RIGID PIPE 5" X 8" Vinyl Siding Standoff (Optional) Horizontal Termination Wall Thimble Pipe Length 90 Elbow Pipe Length Rigid Pipe Adaptor Rigid Pipe Adaptor Horizontal Termination Top Vent - No Vertical Rise • When venting with a 90° elbow directly off the unit, must use 5"...
  • Page 33: Venting Arrangements-Horizontal Terminations

    installation VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS RIGID PIPE 4" X 6-5/8" (MUST USE REDUCER PART # 946-606 & 770-994 RIGID PIPE ADAPTOR) The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 two 45 elbows equal one 90 elbow).
  • Page 34: Horizontal Or Vertical Terminations

    If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches. Note: The 4" x 6-5/8" Regency Flex Kits (946-515 & 946-516) are not approved for use with this fireplace. Only rigid pipe may be used when 4" x 6-5/8" is used.
  • Page 35: Horizontal Terminations

    installation HORIZONTAL TERMINATIONS TWO (2) 90 ELBOWS (RIGID PIPE 4" X 6 - 5/8") One 90 elbow = Two 45 elbows. Option H + H1 W i t h t h e s e o p t i o n s , 0' Min. 2' Max.
  • Page 36: Venting Arrangements For Vertical Terminations

    installation VENTING ARRANGEMENTS FOR VERTICAL TERMINATIONS RIGID PIPE 4" X 6-5/8" (MUST USE REDUCER PART # 946-606 & 770-994 RIGID PIPE ADAPTOR) The shaded area in the Diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90 elbows, with Rigid Pipe Venting Systems for Propane and Natural Gas.
  • Page 37: Vertical Terminations

    installation VERTICAL TERMINATIONS THREE (3) 90 ELBOWS (RIGID PIPE 4" X 6 - 5/8") One 90 elbow = Two 45 elbows. Option H + H1 V + V1 With these options, max. 0' Min. 2' Max. 2' Min. total pipe length is 30 feet 1' Min.
  • Page 38: Venting Arrangements

    installation VENTING ARRANGEMENTS WITH CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE which the flexible liner will accommodate. However, keep the flexible liner as straight as pos- CONNECTED TO A CHIMNEY FLUE sible, avoid unnecessary bending. SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.
  • Page 39: Vertical Terminations

    installation VERTICAL TERMINATIONS CO-LINEAR FLEX SYSTEM INTO MASONRY FIREPLACES FOR BOTH RESIDENTIAL & MANUFACTURED HOMES The shaded area in the Diagrams show the allowable vertical terminations. Bellavista® B36XTE-10 Gas Fireplace...
  • Page 40: Unit Installation With Horizontal Termination

    installation UNIT INSTALLATION WITH 5) Assemble the desired combination of pipe 7) Ensure that the pipe clearances to and elbows to the appliance adaptor and combustible materials are maintained HORIZONTAL twist-lock for a solid connection. (Diagram 5). Install the termination cap. TERMINATION Note: If installing termination on a vinyl 4"...
  • Page 41: Unit Installation With Horizontal Termination

    installation UNIT INSTALLATION WITH NOTE: Horizontal sections must be sup- ported at intervals not exceeding 3 ASTROCAPXL HORIZONTAL feet (0.9 meter). (Flame picture and DIMENSIONS (946-623/P) TERMINATION performance will be affected by sags in the liner). 5" X 8" VENTING (Flex Vent Systems) 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the...
  • Page 42: Unit Installation With Vertical Termination

    installation 4) Assemble the desired lengths of pipe and elbows. Ensure that all pipes and elbow con- UNIT INSTALLATION WITH nections are in the fully twist-locked position VERTICAL and sealed. TERMINATION 4" X 6-5/8" VENTING (Rigid Vent Systems) Diagram 4 MUST USE REDUCER #946-606 AND RIGID PIPE ADAPTOR Roof Pitch Minimum Vent Height...
  • Page 43: Pilot Adjustment

    Pilot Ignitor be checked using the valve pressure ports on the valve. Note: If you have an incorrect flame pattern, contact your Regency dealer for ® 1) Make sure the valve is in the "OFF" position. B36XTE - LP10 System Data further instructions. 2) Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/8"...
  • Page 44: Conversion From Ng To Lp

    installation B36XTCE/ B36XTE CONVERSION KIT #578-972 FROM NG TO LP for B36XTE using SIT 885 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Remove the pilot shield by removing 2 Unscrew the pilot orifice with the allen Each Kit contains one LP screws.
  • Page 45: Brick Panel Installation

    B36X/XT installation BRICK PANEL INSTALLATION BRICK PANEL INSTALLATION Dangerous operating conditions may occur if the panels are broken. Handle with care. DO NOT FORCE INTO POSITION. 1) Unwrap the Brick Panels from the protective wrapping. 2) Ensure that the logs are not in the unit. Top Panel Back Panel Left Panel...
  • Page 46: Optional Enamel Panel Installation

    B36X / XT installation OPTIONAL ENAMEL PANEL INSTALLATION BLACK ENAMEL PANEL INSTALLATION Black Enamel Panels • Black Enamel panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration. •...
  • Page 47: Log Set Installation

    installation B36XT LOG SET INSTALLATION LOG SET INSTALLATION Installation of Optional Panels must be completed before installing the log set. Read the instructions below carefully and refer to the images. If the 2) Spread vermiculite along the base of the fi rebox. logs are broken do not use the unit until they are replaced.
  • Page 48 B36XT installation 6) Position Log D with the fl at side toward Log E. 5) Place Log A on the front right side of the burner. Position the notch Fit Log D into right peg on Log E. on the bottom right side of the log into the right side of the grate. Slide Log A back towards Log E until the fl...
  • Page 49 B36XT installation 8) Place the lava rocks on the front of the burner tray in the places shown in the photo. Separate platinum embers and place on the front of the burner tray in and around the lava rocks. Avoid stacking platinum embers. Platinum embers may be placed over burner ports.
  • Page 50: Aeration Adjustment

    installation AERATION ADJUSTMENT The burner aeration is factory set but may need CAUTION: Carbon will be produced if air shutter adjusting due to either the local gas supply or is tightly closed. altitude. Open the air shutter for a blue flame or close for a more yellow flame.
  • Page 51: Optional Fan Installation

    B41XTE installation OPTIONAL FAN INSTALLATION OPTIONAL FAN INSTALLATION Important: 120 Volt AC power is needed for the fan switch and blower. 9) Slide the thermodisc/cover assembly onto the bracket clip on the left underside of the fi rebox. Ensure that no wires will touch hot The receptacle box will be installed on the left hand side of the unit and must be wired by a qualifi...
  • Page 52 installation 52 | Bellavista® B36XTE-10 Gas Fireplace...
  • Page 53: Wiring Diagram With Optional Fan

    installation WIRING DIAGRAM WITH OPTIONAL FAN SureFire™ Switch Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Bellavista®...
  • Page 54: Optional Wall Thermostat Installation

    installation OPTIONAL WALL THERMOSTAT INSTALLATION A wall thermostat may be installed if desired. 4) Connect the other thermostat lead to male connector disconnected from Step 1 using a female spade connector - see picture below. Recommended: Wall Thermostat should be mounted beside the Remote/Unit Receiver which comes standard with the appliance.
  • Page 55: Optional Accent Light Installation

    installation OPTIONAL ACCENT LIGHT INSTALLATION OPTIONAL LIGHT INSTALLATION B36XT/B36XTE Accent Light Kit # 576-959 7) When light assembly has been fully seated - secure in place with 2 screws that were removed from the Light Assembly -includes cable tie/ gasket. cover plate 910-997 Halogen Bulb...
  • Page 56 installation 14) Install the halogen bulb supplied with the kit. 11) After the wiring has been connected, secure green ground wire to ground lug as shown below. Important: Use caution - do not touch the bulb during installation. Use the plastic packaging as a protective Ground lug is located on the lower left corner inside the covering while installing the bulb.
  • Page 57 installation BULB REPLACEMENT 17) Reinstall the logs. 18) Reinstall mesh guard and glass door. 1) Follow steps 1- 4 from previous page. 19) Plug the light assembly into the receptacle located on the 2) Remove 2 screws to remove light diffuser plus gasket. bottom left side of the unit.
  • Page 58 installation LINE VOLTAGE WIRING TO RECEPTACLE IN UNIT TO MAKE OUTLETS INDEPENDENT OF EACH OTHER Scheme - 1 Using Wall Switch only to turn lights ON/OFF. Ground Optional Lights Break Tab on Black (hot) side Clamp Connector Ground (Copper) 120 V (60 HZ) power Black (Hot) into receptacle White (Neutral)
  • Page 59: Flush Glass Door Installation

    installation FLUSH GLASS DOOR INSTALLATION 1) Line up slots on flush glass door with tabs in firebox. Hook slots on to tabs and lower door slowly (See Diagram 1). Tabs in Firebox Diagram 1 2) Lower the flush door, then hook the 2 adjustable tension latches - close the latches to secure the flush door(See Diagram 2). Adjustable Tension Latch location Diagram 2...
  • Page 60: Vignette Frame And Safety Screen Installation

    installation VIGNETTE FRAME AND SAFETY SCREEN INSTALLATION B36XTE/B41XTE Black Chrome Handling Instructions All hand and finger marks MUST be cleaned off with a soft cloth. Use an ammonia based cleaner (ie. glass cleaner) to remove any finger prints before applying heat to the unit. Use supplied gloves when installing Black Chrome Faceplates. Failure to do this will result in burn stains on panels which you will be unable to remove.
  • Page 61: Optional Vignette Inlay Installation

    installation OPTIONAL VIGNETTE INLAY OPTIONAL VIGNETTE INLAY INSTALLATION NOTE: Inlay not exactly as shown below. 1. Remove Inner Vignette Frame from unit if already installed. 5. Secure the Inlay in position with supplied brackets, washers, and nuts as shown. 2. Line up the inlay top bracket in the space between the safety screen frame and Vignette Frame.
  • Page 62: Optional Vignette Finishing Trim Installation

    installation B36XTE-10 OPTIONAL VIGNETTE FINISHING TRIM INSTALLATION B36XTE -VIGNETTE FINISHING TRIM *If finishing the unit with the Vignette Finishing Trim - remove top nailing strip from unit if installed–use nailing strip supplied with top trim piece. Side nailing strips are bent around side trim piece in flush finish application. NOTE: Remove the safety screen, Vignette Faceplate Install the lower finishing trim (if required)–secure with four...
  • Page 63: Premium Flush Front Installation

    installation B36XTE-10 PREMIUM FLUSH FRONT INSTALLATION - MUST BE USED WITH SAFETY SCREEN PART #578-929 FLUSH PANEL INSTALLATION- MUST BE USED WITH SAFETY SCREEN PART #578-929 To install the top and bottom Flush Panels: 5. Install the bottom panel to complete the installation. 1.
  • Page 64: Optional Finishing Trim Installation

    installation B36XTE SAFETY SCREEN INSTALLATION - MUST BE USED WITH PREMIUM FLUSH FRONT SAFETY SCREEN INSTALLATION - MUST BE USED WITH OPTIONAL PREMIUM FRONT 1. Hook the safety screen frame onto brackets within the unit in locations shown below. 2. Gently lower screen on to glass door frame–two (2) magnets located on inside lower part of the screen frame will secure the screen to the glass door frame. 3. To remove–reverse steps. Magnet locations 07.23.15 919-590 B36XTe / B41XTe B36XTE OPTIONAL 3 SIDED FINISHING TRIM INSTALLATION SAFETY SCREEN INSTALLATION - MUST BE USED WITH OPTIONAL PREMIUM FRONT OPTIONAL fINIshINg TrIm INsTALLATION...
  • Page 65: Operating Instructions

    operating instructions OPERATING NORMAL OPERATING INSTRUCTIONS SOUNDS OF GAS APPLIANCES 1) Read and understand these instructions before operating this appliance. It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to 2) Check to see that all wiring is correct and the fact that there are various gauges and types enclosed to prevent possible shock.
  • Page 66: Lighting Procedure

    operating instructions LIGHTING PROCEDURE IMPORTANT: The remote control system supplied with this appliance has several options for starting/operating the appliance using the power button 3. After approximately 4 seconds the spark ignition system will spark for 60 and ON/OFF key on the hand held transmitter. seconds to light the main burner.
  • Page 67: Copy Of Lighting Plate Instructions

    operating instructions COPY OF LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 68: Maintenance Instructions

    In the event that you break your glass by impact, person. covered under warranty. purchase your replacement from an authorized Regency dealer only. Replacement glass (Part 5) The appliance and venting system must be #940-357/P) is shipped already installed into inspected before use, and at least annually, the door frame.
  • Page 69: Removing Valve

    maintenance REMOVING VALVE 8) Disconnect the inlet gas line. 9) Disconnect the EV1, EV2, and ground wires 1) Shut off the gas and electrical supply. from the valve - as shown below. 2) Remove the safety screen and/or Flush Panels. 3) Open and remove the glass door.
  • Page 70: Main Assembly

    parts list MAIN ASSEMBLY Part # Description Part # Description 576-084F Top Insulation Plate 578-917 Fan Assembly 576-099 Top Insulation 910-215/P Fan Motor (120 Volts) 556-524 Flue Collar Outer Assembly 556-095 Flue Collar Gasket 911-159 Power Cord (120 Volts) 556-097 Exhaust Gasket 910-142 Thermodisc - Fan Auto...
  • Page 71 parts list MAIN ASSEMBLY FAN SWITCH ASSEMBLY Bellavista® B36XTE-10 Gas Fireplace...
  • Page 72: Burner Assembly

    parts list BURNER ASSEMBLY Part # Description Part # Description 576-077 Rear Log Tray 911-012 Ignition Board (DBC) 911-013 Wiring Harness -Switch 576-525 B36XTE Burner Assembly 911-018 Battery Holder 576-057 B36XTE Grate Assembly 911-037 Flame Sensor 911-038 Flame Electrode 904-644 Orifice # 35 NG 911-039 Pilot Hood...
  • Page 73: Optional Accessories

    parts list OPTIONAL ACCESORIES Part # Description 576-916 Flush Panels 578-929 Safety Screen 578-928 Vignette Trim 578-918 Vignette Inlay Chrome 578-919 Vignette Inlay Black 578-920 Vignette Inlay Sunset Bellavista® B36XTE-10 Gas Fireplace...
  • Page 74 notes 74 | Bellavista® B36XTE-10 Gas Fireplace...
  • Page 75: The Warranty: Limited Lifetime

    Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option, through an accredited distributor or agent provid- ed that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
  • Page 76 Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Bellavista B36XT Video Regency®, Bellavista®,Surefire™, and AstroCap™ are trademarks of FPI Fireplace Products International Ltd. © Copyright 2015, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...

Table of Contents