Horizontal Or Vertical Terminations; Rigid Pipe 4" X 6-5/8 - Regency Bellavista B36XTE Owners & Installation Manual

Hide thumbs Also See for Bellavista B36XTE:
Table of Contents

Advertisement

installation
|
30
The minimum components required for a basic horizontal termination using 4" x 6-5/8" are:
1
Rigid Pipe Adaptor (770-994)
1
Reducer (946-606)
1
90
Elbow
o
1
Wall Thimble
1
Length of pipe to suit wall thickness
1
Horizontal Termination Cap
Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips
may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into
siding. Measure the wall thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.
Note:
The 4" x 6-5/8" Regency Flex Kits (946-515 & 946-516) are not approved for use with this fireplace. Only rigid pipe may be used
when 4" x 6-5/8" is used.
Vertical
Termination
Cap
Storm Collar
Flashing
Ceiling Firestop
Pipe Length
43"
(1092 mm)
The FPI AstroCap
TM
American Metal Products, Security Secure Vent
International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
30 |
Regency Bellavista™ B36XTE-10 Gas Fireplace

HORIZONTAL OR VERTICAL TERMINATIONS

(MUST USE REDUCER PART # 946-606 & 770-994 RIGID PIPE ADAPTOR)
A
Vinyl Siding
Standoff (Optional)
Pipe Length
o
90 Elbow
Pipe
Length
Reducer
(4" x 6-5/8" venting)
Rigid Pipe Adaptor
and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent
, AmeriVent Direct Vent, ICC Excel. AstroCap
®

RIGID PIPE 4" X 6-5/8"

B
Astrocap
(946-523/P)
Wall Thimble
ASTROCAP # 946-523/P
DIMENSIONS
11"
(279mm)
WARNING:
Do not combine venting components from
different venting systems.
Exception: However, use of the AstroCap
FPI Riser is acceptable with all systems.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with DuraVent Direct Vent, Selkirk Direct-Temp,
Ameri Vent Direct Vent, Security Secure Vent
and ICC Excel Venting Systems. Use of these
systems with the Rigid Pipe Adaptor is deemed
acceptable and does not affect the Intertek WHI
listing of components.
is the proprietary trademark of FPI Fireplace Products
TM
11"
(279mm)
and
TM
Direct Vent,
®