SiBE06-708
2.3

Removal of the Electrical Box

Procedure
Step
Remove the top panel
and the front panel.
1. Remove the shield plate.
1
Loosen the 2 screws.
2
Slide the cover upward
to undo the one hook
on the bottom left, and
then remove the plate.
3
Disconnect the 2 power
supply cables and the 1
earth wire.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Outdoor Unit : 50 Class