Indoor Unit
1.6

Removal of the Heat Exchanger

Procedure
Step
Make sure that the gases
are removed after the
pump down work. After
that, start the removal of
the heat exchanger.
1
Remove the flared joint
from the liquid pipe and
gas pipe using 2
wrenches.
2
Press the right hook to
the inner side and undo
it. After that, undo the
left hook.
3
Undo the 2 hooks from
the left side of the heat
exchanger.
4
Undo the top and
bottom hooks at the
right side, pull the heat
exchanger to your side
to remove.
162
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Hooks
Left
hook
(R6818)
SiBE06-708
Points
Right
hook
(R6817)
Hook
Hook
(R6819)
Removal Procedure