SiBE06-708
1.7

Removal of the Fan Rotor / Fan Motor

Procedure
Step
1. Removing the fan rotor.
1
Remove the 4 screws
from the bellmouth.
2
Remove the nut to
remove the fan rotor.
2. Removing the fan motor.
1
Unhook the harness
from the fan motor.
2
Remove the 3 screws
and remove the fan
motor.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Nut
Hook
(R6821)
(R6822)
Indoor Unit
Points
163