SiBE06-708
Step
3
Unscrew the washer-
fitted nut (M10) of the
propeller fan
with a
spanner.
Remove the 4 screws
4
from the
fan
motor.
Removal Procedure
Procedure
Outdoor Unit : 50 Class
Points
Align
mark of the
propeller fan with D-cut
section of the motor shaft
when reassembling.
171