Outdoor Unit : 50 Class
2.7

Removal of the Compressor

Procedure
Step
Remove the
terminal
1
cover.
2
Disconnect the lead
wires of the
compressor.
184
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
SiBE06-708
Points
Be careful so as not to burn
the compressor terminals or
the name plate.
Make a note.
U
V
W
U : red
V : yellow
W: blue