Daikin FVXS25FV1B Service Manual page 168

Inverter pair floor standing type
Hide thumbs Also See for FVXS25FV1B:
Table of Contents

Advertisement

SiBE06-708
Step
4. Removing the display
PCB.
1
Undo the 2 hooks.
2
Disconnect the
connector and remove
the display PCB.
5. Removing the control
PCB.
1
Cut the cable lock belt
and pull the all Faston
terminals out from the
power terminal board.
2
Disconnect each
connector.
S26:
From the service PCB
S46:
From the display PCB
S48:
From the sensor PCB
Removal Procedure
Procedure
Hooks
Faston
terminal
(R6796)
Display PCB
(R6797)
Cable lock
(R6798)
S48
S26
S46
(R6799)
Indoor Unit
Points
157