5. Enter the IP address of the IMM2 in the space that is provided under the IP address as
seen in Figure 7-8.
Figure 7-8 IBM Systems Director discovery pane
6. An IMM2 is considered a server object in IBM Systems Director. To specify the IMM2 as a
Server object, click the Select the resource type to discover list box and select Server.
7. Click Discover Now when you are ready to discover the IMM2.
8. The discovered IMM2 appears at the bottom of the System Discovery pane under
Discovered Manageable Systems. At this point, the IMM2 has been discovered but has
not been authenticated to. Notice the No Access status under the Access column. Before
authenticating to the IMM2, we advise that you rename it first. The renaming process can
be performed at a later stage as well, but we advise that you perform this process at
discovery time, because it is easier to identify individually discovered IMM2s for renaming
than when they are in a group.
9. To rename the IMM2, right-click the IMM2 server object in the Discovered Manageable
Systems area and click Rename, as shown in Figure 7-9.
Figure 7-9 IBM Systems Director Discovery menu
Chapter 7. Management