Power Subsystem - IBM x3850 X6 Planning And Implementation Manual

Hide thumbs Also See for x3850 X6:
Table of Contents

Advertisement

Table 3-26 shows which components are hot-swap and which are not.
Table 3-26 Hot-swap capabilities
Component
Compute Book
Storage Book
Primary I/O Book
Optional I/O Books
Disk drives
Compute Book fans
Primary I/O Book fans
Power supplies
For additional information about hot-swap capabilities of the Optional I/O Books, see 3.14,
"Hot-swap adapter support" on page 91.

3.22 Power subsystem

The x3850 X6 server supports up to four power supplies and the x3950 X6 supports up to 8
power supplies. Power supplies are hot-swap. Options available are listed in Table 3-27.
Table 3-27 Power supply options
Part
Feature
Description
number
code
44X4132
A4R0
IBM 900W Power Supply
44X4152
A54E
IBM 1400W HE Redundant Power Supply
(not certified for altitudes above 5000 m)
44X4150
A54D
IBM 1400W HE Redundant Power Supply
for altitudes above 5000 meters
88Y7433
A2EA
IBM 750W High Efficiency -48 V DC Power
Supply
a. The only exception to the rule of a minimum of two power supplies is model 3837-A4x which has a minimum of 1.
Each installed AC power supply ships standard with one 2.8 m C13 - C14 power cord.
Configuration rules are as follows:
Power supplies must be in pairs (x3850 X6) or quads (x3950 X6), with the exception of
model 3837-A4x, where one power supply is supported.
The AC power supplies can be mixed. For example, these are valid combinations for the
x3850 X6:
– Two 44X4132 and two 44X4152
– Two 44X4132 and two 44X4150
Hot-swap ability
No
No
No
Yes
Yes
Yes
Yes
Yes
Supported
Supported
quantities
quantities
x3850 X6
x3950 X6
a
2, 4
4, 8
2, 4
4, 8
2, 4
4, 8
2, 4
4, 8
Chapter 3. Product information
Models
where
used
A4x, B1x, B3x, C1x,
C4x, BAx, CAx, CCx
-
All HANA models
-
101

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3950 x6

Table of Contents