Engine Oil/Oil Filter; Oil Level Inspection - Honda CBF600SA Service Manual

Table of Contents

Advertisement

Manuals by Motomatrix / www.motomatrix.co.uk / The Solution For Lost Motorcycle Coded Keys.
MAINTENANCE
Apply engine oil to the timing hole cap O-ring.
Check that the O-
Apply grease to the timing hole cap threads.
ring is in good
condition, replace if
Install and tighten the timing hole cap to the speci-
necessary.
fied torque.
TORQUE: 18 N·m (1.8 kgf·m, 13 lbf·ft)
Remove the cam chain tensioner stopper tool.
Install a new sealing washer and cam chain ten-
sioner lifter sealing bolt.
Tighten the bolt securely.
Install the cylinder head cover (page 8-31).

ENGINE OIL/OIL FILTER

OIL LEVEL INSPECTION

Place the motorcycle on the level ground with its
sidestand.
Start the engine and let it idle for 3 – 5 minutes.
Stop the engine and wait 2 – 3 minutes.
Hold the motorcycle in an upright position.
Check the oil level through the inspection window.
If the level is below the lower level line, fill the
crankcase with the recommended oil up to the
upper level line as following procedures.
Remove the oil filler cap.
3-14
email: info@motomatrix.co.uk
O-RING
TIMING HOLE CAP
BOLT
CAM CHAIN TENSIONER LIFTER
SEALING WASHER
INSPECTION WINDOW
OIL FILLER CAP
UPPER LEVEL LINE
LOWER LEVEL LINE