LUBRICATION SYSTEM
Install and tighten the EOP switch to the specified
torque.
TORQUE: 12 N·m (1.2 kgf·m, 9 lbf·ft)
Connect the EOP switch wire and tighten the termi-
nal bolt to the specified torque.
TORQUE: 2.0 N·m (0.2 kgf·m, 1.5 lbf·ft)
Instal the rubber cap securely.
Start the engine.
Check that the oil pressure indicator goes off after
one or two seconds. If the oil pressure indicator
stays on, stop the engine immediately and deter-
mine the cause (page 20-28).
OIL STRAINER/PRESSURE RELIEF
VALVE
REMOVAL
Drain the engine oil (page 3-15).
Remove the exhaust pipe (page 2-11).
Remove the flange bolts and the oil pan.
Loosen the bolts in
a crisscross pattern
in two or three
steps.
Remove the oil strainer and packing.
Clean the oil strainer screen.
4-6
email: info@motomatrix.co.uk
EOP SWITCH
RUBBER CAP
BOLTS

OIL STRAINER

TERMINAL BOLT
EOP SWITCH
OIL PAN
PACKING