lldp medFastStartCount

This command specifies the amount of MED Fast Start LLDPDUs to transmit during
the activation process of the LLDP-MED Fast Start mechanism.
Syntax
lldp medfaststartcount packets
seconds - Amount of packets. (Range: 1-10 packets; Default: 4 packets)
Default Setting
4 packets
Command Mode
Global Configuration
Command Usage
The MEDFastStartCount parameter is part of the timer which ensures that the
LLDP-MED Fast Start mechanism is active for the port. LLDP-MED Fast Start
is critical to the timely startup of LLDP, and therefore integral to the rapid
availability of Emergency Call Service.
Example
Console(config)#lldp medfaststartcount 6
Console(config)#

lldp notification-interval

This command configures the allowed interval for sending SNMP notifications about
LLDP MIB changes. Use the no form to restore the default setting.
Syntax
lldp notification-interval seconds
no lldp notification-interval
seconds - Specifies the periodic interval at which SNMP notifications are
sent. (Range: 5 - 3600 seconds)
Default Setting
5 seconds
Command Mode
Global Configuration
Command Usage
• This parameter only applies to SNMP applications which use data stored in
the LLDP MIB for network monitoring or management.
• Information about changes in LLDP neighbors that occur between SNMP
notifications is not transmitted. Only state changes that exist at the time of a
4
LLDP Commands
4-289