Mantel Requirements; Hearth Requirements - FireplaceXtrordinair 36DV-A/R Owner's Manual

Built-in direct vent fireplace natural gas or propane residential or mobile home
Hide thumbs Also See for 36DV-A/R:
Table of Contents

Advertisement

+ Facing may be installed so it inserts behind the faceplate but not below it (see illustration below).
Detail of
Faceplate
NOTE:
+ To achieve a facing that is flush with the drywall to the side of the fireplace, recess the framing
directly next to the fireplace. See the illustration below.
TOP
VIEW
Fireplace
1"
Faceplate

Mantel Requirements

¥
The optional mantel must be a min. 24" above the top of the faceplate.

Hearth Requirements

¥
The hearth must extend 16" in
front of the faceplate. It must
also match the width of the
faceplate (36" wide, centered on
the fireplace).
¥
The hearth must be made of a
non-combustible material at
least 3/8" thick (it must not raise
more than 7/8" above the base of
the fireplace).
I
NSTALLATION
NOTE:
The set-up face is 1/16" larger in
each dimension (sides, and height)
than the finish face. This allows for
expansion during operation.
Do not tuck tile underneath the faceplate on
the bottom (there will be a 1/2" air space
below the access door). You may do this
on the sides and top, but not on the bottom.
This 2x4 is recessed 3/8"
to make a flush facing
1/2" Concrete Board
3/8" Tile
(C
.)
ONT
The overlap is 1-1/2" along
the top of the faceplate.
Finish
Faceplate
Glass
Access Door
Air Space
Fireplace
1/2" Drywall
1"
Faceplate
24" on the 36DV-A
22" on the 36DV-R
Minimum
Mantel
Clearance
36DV-A
- For Qualified Installers Only!
1/4" on the 36DV-A
2-1/4" on the 36DV-R
1"
1/2"
1"
1/2" Concrete Board
The tile overlaps the drywall
3/8" Tile
for an overlap facing
36DV-R
P
AGE
1/2" Drywall
Mantel (may be
combustible)
Minimum Hearth
Depth (must be
36" wide)
16"
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents