Burner Installation - FireplaceXtrordinair 36DV-A/R Owner's Manual

Built-in direct vent fireplace natural gas or propane residential or mobile home
Hide thumbs Also See for 36DV-A/R:
Table of Contents

Advertisement

F
INALIZING THE
3 Install the burner pan following the instructions below:
a Install a manual shutoff valve and the included 10" flex tube to the gas line. The illustration
below details the location of the gas valve Ð make sure the gas line is correctly located to
allow hookup of the flex line to the gas control valve.
The 1" diameter access hole is located 1-7/8" above the base of the fireplace. Cut
an "X" in the gasket covering the inlet and insert the gas line through the gasket.
6-5/8"
-- OR --
-- OR --
b Remove the burner pan from the packaging, place it upside down, and remove the boxing
brackets (they may be discarded).
Natural gas burner pans have
a blue mark here. Propane
burner pans have a red mark.
I
NSTALLATION
21"
4-1/2"
The included
fitting accepts a
3/8" M.P.T. or
1/2" F.P.T.
Boxing Bracket
Burner Pan
(C
.)
ONT
- For Qualified Installers Only!
A shutoff valve may be
placed within the fireplace
If the gas line is routed from the
right side, bend the flex tube 180¡.
3/8" M.P.T to 1/2" O.D. Fitting
(Factory installed)
10" Flex Tube
(shipped with the fireplace - min. bending radius is 3/4")
Remove the four nuts holding
the boxing brackets in place.
Boxing Bracket
Gas Control Valve
PILOT ADJ
7/16Ó
Socket
P
21
AGE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents