Remote Control Thermostat - FireplaceXtrordinair 36DV-A/R Owner's Manual

Built-in direct vent fireplace natural gas or propane residential or mobile home
Hide thumbs Also See for 36DV-A/R:
Table of Contents

Advertisement

O
PTIONAL
P
38
AGE

Remote Control Thermostat

!
Do not connect 120 VAC to the gas control valve or wiring system of this unit.
1 Turn the gas control valve to "OFF". Install a standard 9 volt battery into both the remote control
receiver and remote control.
Slide the cover off of the
back of the remote
control to access the
battery holder.
2 Attach the remote control wire and route through the gas inlet hole (see the illustration below). Pull
through all the slack (you may wish to wrap the wire in electrical tape to prevent damaging the wire).
3 Determine a location for the receiver (a maximum 50' of wire may be used). Cut a 1-3/4" wide by 2-
1/2" tall hole in the wall for the receiver (see the illustration below). Attach 18 gauge thermostat
wire (not supplied) to the remote wire and route to the remote control receiver location (wire may be
routed behind the wall or externally). Attach quick-connects to the receiver end of the wire and
attach to the receiver (orientation does not matter). Attach the receiver and cover plate to the wall
(you may be required to use a junction box behind the wall).
IMPORTANT OPERATIONAL NOTE FOR REMOTE THERMOSTAT USE:
Included with the remote thermostat is a set of instructions that should be given to the homeowner.
Please be aware that the remote thermostat has a 1 to 2 minute lag time between the time the
thermostat is turned up and the heater turns on.
E
QUIPMENT
(Part # 99300652)
Install a 9 volt battery in
both the remote control and
remote control receiver.
Side of
Fireplace
b
Route the wire through
Faceplate
the gas inlet hole
Remote Control
Receiver
Cover Plate
The distance between the
mounting holes is 3 1/4".
The mounting screws insert here
(screws not included)
(C
)
ONTINUED
This clip holds the
battery in place.
Wire
Green
Jumper
4
1
Wire
5
2
Back of on/off switch
Remove and discard the jumper wire on the back of the
on/off switch. Attach the quick connects on the end of the
wire to the two posts the jumper wire was attached to.
The hole must
be 1 3/4" wide.
Remote
Control Wire
Remote
Control
Receiver
(with cover
plate
removed)
PILOT
ON
IGNITER
OFF
a
The hole must
be 2 1/2" tall.