I
NSTALLATION
P
8
AGE
Corner Installations
¥
A typical 45° installation uses
the minimum framing
dimensions shown in the
illustration to the right (NOTE:
all clearances still apply).
Raised Fireplaces
+ The fireplace (and
hearth if desired) may
be placed on a platform
designed to support the
fireplace (250 Lbs.) and
vent. The hearth
requirements stay the
same.
Facing Requirements
¥
The non-combustible facing
must extend 10" above and
4-1/2" to each side of the
faceplate.
¥
The fireplace requires 1/2" thick
concrete-board to extend from
the header to the floor and to the
framing members on both sides
(do not use sheetrock or
drywall).
¥
The fireplace is shipped with a set-up face that is 1/16" larger on each side and top than the
faceplate. Use the set-up face as a template when installing the facing.
(C
.)
ONT
- For Qualified Installers Only!
14-1/2"
46-1/4"
Raised fireplace
Hearth
Raised
Platform
10"
4-1/2"
12-3/4"
Fireplace
(includes
1/2"
standoffs)
19-5/8"
43"
65-1/2"
11-1/4"
Raised fireplace with
raised hearth.
Raised
Platform
Raised Hearth
Nail the nail down plates to the floor
(or raised platform)
36DV-R
36DV-A
Cement-board must
extend from the header
to the floor and to the
framing members on
both sides.
Non-combustible
Facing
4-1/2"
Keep the set-up face
on the fireplace when
installing the facing.