Approved Configurations With No Elbows Or Two 45° Offsets (Vertical Termination) - FireplaceXtrordinair 36DV-A/R Owner's Manual

Built-in direct vent fireplace natural gas or propane residential or mobile home
Hide thumbs Also See for 36DV-A/R:
Table of Contents

Advertisement

I
NSTALLATION
P
14
AGE
Approved Venting Configurations for
Vertical Terminations with (or without)
Two 45° Elbows
¥
10' Minimum System Height (with or
without offsets)
¥
34' Maximum System Height
¥
6' Maximum Offset
¥
The termination must fall within the shaded
area shown in the chart. Use the indicated
restrictor position.
Vertical
Rise
Offset Length
None
1' Section
2' Section
3' Section
4' Section
4' + 1' Section
4' + 2' Section
4' + 3' Section
4' + 4' Section
(C
ONT
Horizontal
Offset
Offset
Length
Hor. Offset
Vert. Rise
5"
1'
1' 7"
1' 9"
2' 4"
2' 5"
3' 2"
3' 8"
3' 9"
4' 4"
4' 6"
5' 2"
5' 9"
6'
6' 9"
.)
- For Qualified Installers Only!
36' (max)
30 feet
25 feet
20 feet
15 feet
1'
10 feet
3'
8' (min)
5'
5 feet
0 feet
36' (max)
Restrictor
Position # 9
30 feet
25 feet
NOTE:
Restrictor positions
are based upon lab
tests. The ideal
restrictor position
may vary slightly,
especially when the
termination is near
a demarkation line.
20 feet
Restrictor
Position # 8
15 feet
Restrictor
Position # 7
10 feet
8' (min)
The maximum
5 feet
offset lengths is
two 4' sections.
0 feet