Simulation
Code
Main Sub.
46
23
Half tone high density
correction setup
24
Print (printer engine) copy
color balance/density
(gamma) adjustment (auto
adjustment)
(AR-C150/C250)
25
Copy color balance
adjustment (Mono color
copy mode)
26
Copy color balance
default setup (Mono color
copy mode)
27
Black toner component
image gamma adjustment
48
01
Copy magnification ratio
adjustment
06
Motor RPM adjustment
∗1: AR-C160/C270
Content/Item
C (RED)
C (GREEN)
C (BLUE)
C (PURPLE)
C (ORANGE)
C (BROWN)
M (RED)
M (GREEN)
M (BLUE)
M (PURPLE)
M (ORANGE)
M (BROWN)
Y (RED)
Y (GREEN)
Y (BLUE)
Y (PURPLE)
Y (ORANGE)
Y (BROWN)
C (RED)
C (GREEN)
C (BLUE)
C (PURPLE)
C (ORANGE)
C (BROWN)
M (RED)
M (GREEN)
M (BLUE)
M (PURPLE)
M (ORANGE)
M (BROWN)
Y (RED)
Y (GREEN)
Y (BLUE)
Y (PURPLE)
Y (ORANGE)
Y (BROWN)
A: Color mode
∗1
B: Monochrome mode
A: Sub scanning direction copy
magnification ratio adjustment
B: Main scanning direction copy
magnification ratio adjustment
A: Resist motor speed
B: Transfer belt speed
C: Fusing rotation speed (greater
than B4)
D: Fusing rotation speed (smaller
than B4)
E: Drum motor speed
(Black/White)
F: Drum motor speed (Color)
G: Paper feed transfer motor
speed
H: Developing motor (Black/White)
I: Developing motor (Color)
Model
Set range
Default
AR-
AR-
C100
C150
❍
ON/OFF
OFF
❍
0 – 255
0
0 – 255
255
0 – 255
255
0 – 255
148
0 – 255
38
0 – 255
131
0 – 255
255
0 – 255
0
0 – 255
255
0 – 255
238
0 – 255
140
0 – 255
255
0 – 255
255
0 – 255
255
0 – 255
0
0 – 255
105
0 – 255
255
0 – 255
229
0 – 255
0
0 – 255
255
0 – 255
255
0 – 255
148
0 – 255
38
0 – 255
131
0 – 255
255
0 – 255
0
0 – 255
255
0 – 255
238
0 – 255
140
0 – 255
255
0 – 255
255
0 – 255
255
0 – 255
0
0 – 255
105
0 – 255
255
0 – 255
229
0 – 100
50 (70)
0 – 100
50
❍
❍
1 – 30
15
❍
❍
1 – 99
50
❍
❍
1 – 99
55
❍
❍
1 – 99
51
❍
❍
1 – 99
40/45/
50/55
❍
❍
1 – 99
40/55
50/60
❍
❍
1 – 99
42
❍
❍
1 – 99
37
1 – 99
50
1 – 99
50
1 – 99
50
14 – 15A
NOTE
AR-
AR-
C160/
C250
C270
❍
❍
❍
❍
The adjustment value
cannot be entered
directly.
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
( ) AR-C160/C270
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
The set value
(default) differs
❍
❍
depending on the
destination.
❍
❍
❍
❍
❍
❍
❍
Data store
location
EEPROM
(ICU PWB)
EEPROM
(ICU PWB)
EEPROM
(ICU PWB)
EEPROM
(ICU PWB)
EEPROM
(ICU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)