Main
Sub
Model
code
code
AR-C100,
F2
80
Half tone process control 1st batch
AR-C150,
trouble (Black)
AR-C250,
81
Half tone process control 1st batch
AR-C160,
trouble (Cyan)
AR-C270
82
Half tone process control 1st batch
trouble (Magenta)
83
Half tone process control 1st batch
trouble (Yellow)
84
Half tone process control 2nd batch
trouble (Black)
85
Half tone process control 2nd batch
trouble (Cyan)
86
Half tone process control 2nd batch
trouble (Magenta)
87
Half tone process control 2nd batch
trouble (Yellow)
90
Half tone process control error
F3
12
Cassette 1 lift up trouble
22
Cassette 2 lift up trouble
32
Cassette 3 lift up trouble
42
Cassette 4 lift up trouble
AR-C150,
F9
00
ICU-PRT communication trouble (ICU
AR-C250,
detection)
AR-C160,
AR-C270
AR-C100,
H2
00
Thermistor open/Fusing unit not installed
AR-C150,
(HL1)
AR-C250,
01
Thermistor open/Fusing unit not installed
AR-C160,
(HL2)
AR-C270
02
Thermistor open/Fusing unit not installed
(HL3)
AR-C100,
H2
03
Thermistor open/Fusing unit not installed
AR-C150,
(HL4)
AR-C250
The thermistor is open. (The input
voltage of 4.6V or more is detected.) The
fusing unit is not installed.
H3
00
Fusing section high temperature trouble
(HL1)
01
Fusing section high temperature trouble
(HL2)
02
Fusing section high temperature trouble
(HL3)
03
Fusing section high temperature trouble
(HL4) The fusing temperature exceeds
220 C. (The input voltage of 0.85V or
less is detected.) Thermitor trouble,
control PWB trouble, fusing section
connector trouble, AC power trouble
H4
00
Fusing section low temperature trouble
(HL1)
01
Fusing section low temperature trouble
(HL2)
H5
01
3-time continuous detection of
POD/DPID not-reaching jam
H6
00
Fusing oil remaining quantity abnormality
detection
H7
00
AC input voltage (HLV) abnormality
detection
AR-C100,
L1
00
Mirror feed trouble
AR-C150,
L3
00
Mirror return trouble
AR-C250,
L4
03
Fusing motor trouble
AR-C160,
04
Developing motor trouble (Black)
AR-C270
05
Developing motor trouble (Color)
06
Transfer belt lift motor trouble
Content
8 – 12
Main
Sub
Model
code
code
AR-C100,
L6
10
Polygon motor lock detection (Black)
AR-C150,
11
Polygon motor lock detection (Cyan)
AR-C250,
12
Polygon motor lock detection (Magenta)
AR-C160,
13
Polygon motor lock detection (Yellow)
AR-C270
L8
01
No full wave signal
02
Full wave signal abnormality
PF
00
RIC copy inhibition signal reception
U0
00
OPE-PCU sub communication trouble
(OPE/PCU detection)
80
PCU-PCU sub communication trouble
(PCU detection)
U2
00
EEPROM read/write error (PCU
detection)
11
Counter check sum error(PCU)
12
Adjustment value check sum error (PCU)
20
EEPROM read/write error (ICU)
21
Counter check sum error (ICU)
22
Adjustment value check sum error (ICU)
30
Manufacturing No. data discrepancy
U4
00
ADU communication trouble
02
ADU alignment plate operation
abnormality
12
ADU transport motor trouble
U5
00
ADF communication trouble
01
ADF resist sensor error
02
ADF repulsion sensor error
03
ADF timing sensor error
11
Paper fed motor operation trouble
AR-C150,
U6
09
LCC lift motor trouble
AR-C250,
20
LCC communication trouble
AR-C160,
21
LCC transport motor trouble
AR-C270
22
LCC 24V power abnormality
AR-C100,
U7
00
RIC communication trouble
AR-C150,
UC
00
CPT board communication trouble
AR-C250,
01
CPT board program hung up
AR-C160,
02
CPT board ASIC abnormality
AR-C270
03
CPT board ROM abnormality
04
CPT board RAM abnormality
05
CPT board model code abnormality
22 - 10
Purpose
Operation data output/Check (Display/Print)
Function
Used to check the system configuration (option, internal
(Purpose)
hardware). (AR-C150/C250/C160/C270)
Item
Specifications
Operation/
This simulation allows to check the system configura-
Procedure
tion.
The devices and the option units which are installed are
displayed with the model names, etc.
Content
Options

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-c250Ar-c160Ar-c270

Table of Contents