3) Remove the parts, and remove the paper exit roller
(S07/Ua02/P02/CLN).
Clean with alcohol.
S07/Ua02/P04/CLN/GRE
S07/Ua02/P02/CLN
Apply grease to the gear (S07/Ua02/P03/GRE) and the inside
of the paper exit idle roller (S07/Ua02/P04/CLN/GRE).
S10
PWB
S10/P01
ICU main PWB
S10/P02
ICU image PWB
S10/P03
ICU scan PWB
(AR-C150/C250)
1)
Remove the original cover. S01/P01
2)
Remove the rear cover upper. S01/P02
3)
Remove the glass holder right. S01/P05
4)
Remove the glass holder left. S01/P06
5)
Remove the table glass. S01/P07
6)
Remove the shading glass AS. S01/P08
7)
Remove the operation unit. S02/Ua01
8)
Remove the screw, and remove the dark box cover.
9)
Remove the screw, and remove the flat cable holder.
10) Remove the flat cable from the CCD.
11) Remove the screw, and remove the scanner fixing angle.
12) Remove the screw, and remove the stopper.
13) Open the scanner (reading) unit. Support it with the stopper.
14) Remove the screw, and remove the ICU cover.
S07/Ua02/P03/GRE
15) Remove the ICU main PWB, the ICU image PWB, and the ICU
S04/Ua01
11 – 32
scan PWB.