Sharp AR-C150 Service Manual page 205

Digital full color copier
Hide thumbs Also See for AR-C150:
Table of Contents

Advertisement

Simulation
Code
Main Sub.
26
55
Fusing capability (Image
process) setup in the
heavy paper mode
(AR-C150)
Select the gamma
characteristics in the color
copy mode (AR-C250)
27
01
PC/MODEM
communication trouble
(U7-00) detection
YES/NO setup
02
Host computer/Modem
number setup
03
Machine/Host computer
MODEM ID number setup
05
Tag number setup
06
Manual service call
Enable/Disable setup
29
04
Printer mode fee-charging
setup
40
02
Manual feed tray paper
width detection level
adjustment
05
OHP sensor detection
level adjustment
06
OHP sensor adjustment
parameter set up
41
02
Original size sensor
adjustment
43
01
Fusing temperature setup
(AR-C100/C150)
∗2: AR-C250/C270
Content/Item
ENABLE/DISABLE
ENABLE/DISABLE
A: PC/MODEM communication
trouble (U7-00) detection
YES/NO
Host computer/MODEM number
Machine/Host computer modem
ID number
Tag number
A: Manual service call YES/NO
A: Paper guide max. position level
B: Paper guide min. position level
A: OHP sheet use Enable/Disable
setup
B: OHP sensor adjustment target
level
C: OHP paper judgement
reference level
Adjustment value (PD1 – 7)
A: Temperature set value (upper)
B: Temperature set value (lower)
C: Temperature set value (Ready
upper)
D: Temperature set value (Ready
lower)
E: Temperature set value (Energy
saving upper)
F: Temperature set value (Energy
saving reset)
G: Temperature set value (Thick
paper upper)
H: Temperature set value (Thick
paper lower)
I: Temperature set value (OHP
upper)
J: Temperature set value (OHP
lower)
Model
Set range
Default
AR-
AR-
C100
C150
ON/OFF
ON/OFF
0 – 1
0
0 – 1
0
0 – 2
0
(0 – 4) ∗2
0 – 1
1
0 – 255
200
0 – 255
120
0 – 255
128
70 – 200
70 – 200
70 – 200
70 – 200
70 – 200
70 – 200
70 – 200
70 – 200
70 – 200
70 – 200
14 – 10A
NOTE
AR-
AR-
C160/
C250
C270
The default value
differs depending on
the destination.
The default value
differs depending on
the destination.
The adjustment value
cannot be entered
directly.
The adjustment value
cannot be entered
directly.
The adjustment value
cannot be entered
directly.
The set value
(default) differs
depending on the
destination. Refer to
the details of SIM
43-01.
Data store
location
EEPROM
(ICU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-c250Ar-c160Ar-c270

Table of Contents