Display
A: HL1 PLAIN
Normal mode control
PAPER
temperature (HL1)
B: HL2 PLAIN
Normal mode control
PAPER
temperature (HL2)
C: HL1 READY
Ready state control
temperature (H1)
D: HL2 READY
Ready state control
temperature (H2)
E: HL1 E_STAR
Energy save mode control
temperature (HL1)
F: HL1 PRE_BK
Control temperature (HL1)
when resetting to B/W
from preheat
G: HL1
Heavy paper mode control
HEAVYPAPER
temperature (HL1)
H: HL2
Heavy paper mode control
HEAVYPAPER
temperature (HL2)
I: HL1
OHP mode control
TRANSPARENCY
temperature (HL1)
J: HL2
OHP mode control
TRANSPARENCY
temperature (HL2)
(AR-C250/C160/C270)
Display
A: HL1 PLAIN
Normal mode control
PAPER
temperature (HL1)
B: HL2 PLAIN
Normal mode control
PAPER
temperature (HL2)
C: HL1 READY
Ready state control
temperature (H1)
D: HL2 READY
Ready state control
temperature (H2)
E: HL1 E_STAR
Energy save mode control
temperature (HL1)
F: HL1 PRE-BK
Control temperature (HL1)
when resetting to B/W
from preheat
G: HL1
Heavy paper 1 mode
HEAVYPAPER1
control temperature (HL1)
H: HL2
Heavy paper 1 mode
HEAVYPAPER1
control temperature (HL2)
I: HL1
Heavy paper 2 mode
HEAVYPAPER2
control temperature (HL1)
J: HL2
Heavy paper 2 mode
HEAVYPAPER2
control temperature (HL2)
K: HL1
OHP mode control
TRANSPARENCY
temperature (HL1)
L: HL2
OHP mode control
TRANSPARENCY
temperature (HL2)
Set
Content
range
U.S.A Canada
70 to
180
200
70 to
135
200
70 to
187
200
70 to
142
200
70 to
140
200
70 to
155
200
70 to
200
200
70 to
155
200
70 to
180
200
70 to
175
200
Set
Content
range
U.S.A Canada
70 to
170
200
70 to
125
200
70 to
177
200
70 to
132
200
70 to
136
200
(146)
70 to
148
200
(158)
70 to
185
210
70 to
155
200
70 to
200
210
70 to
155
200
70 to
180
200
70 to
175
200
43
43 - 1
Purpose
Setting
Function
Used to set the fusing temperature in each operation
(Purpose)
mode.
Section
Fixing (Fusing)
Item
Operation
Operation/
1. Select the kind of lamps and the operation mode
Procedure
with [↑], [↓] keys.
2. Enter the set value with the 10-key.
3. Press the [OK] key to set the fusing temperature set in proce-
dure 2.
Set value
Inch
Japan AB_B
180
180
170
170
135
135
125
125
187
187
177
177
142
142
132
132
140
140
140
140
(137)
155
155
155
155
(152)
200
200
200
200
155
155
155
155
180
180
180
180
175
175
175
175
Set value
Inch Japan AB_B Europe
170
170
170
170
140
140
125
125
(125)
(125)
177
177
177
177
140
140
132
132
(132)
(132)
136
136
136
136
(146)
(146)
(146)
(146)
148
148
148
148
(158)
(158)
(158)
(158)
185
185
185
185
155
155
155
155
200
200
200
200
155
155
155
155
180
180
180
180
175
175
175
175
8 – 17
Europe
U.K
Aus.
AB_A
180
180
180
180
135
135
135
135
187
187
187
187
142
142
142
142
140
140
140
140
155
155
155
155
200
200
200
200
155
155
155
155
180
180
180
180
175
175
175
175
U.K
Aus. AB_A
170
170
170
170
( )
125
125
125
125
AR-C160/C270
177
177
177
177
( )
132
132
132
132
AR-C160/C270
136
136
136
136
( )
(146)
(146)
(146)
(146)
AR-C160/C270
( )
148
148
148
148
AR-C160/C270
(158)
(158)
(158)
(158)
185
185
185
185
155
155
155
155
200
200
200
200
155
155
155
155
180
180
180
180
175
175
175
175