Simulation
Code
Main Sub.
43
01
Fusing temperature setup
(AR-C250/C160/C270)
07
Fusing oil pump operation
setup
44
01
Image density correction
(Process control)
operation mode setup
04
Image density correction
(Process control) target
level setup
05
Image density correction
(Process control) initial
developing bias voltage
setup
06
Image forming section
correction (Process
control) forcible execution
13
Image density sensor
sense level adjustment
20
OPC drum phase
adjustment (Old)
21
Half tone image correction
initial setup
23
Image density sensor
sense position adjustment
26
Half tone image correction
forcible execution
27
Half tone image correction
data reset
∗1: AR-C160/C270
Content/Item
A: Temperature set value (upper)
B: Temperature set value (lower)
C: Temperature set value (Ready
upper)
D: Temperature set value (Ready
lower)
E: Temperature set value (Energy
saving upper)
F: Temperature set value (Energy
saving reset)
G: Temperature set value (Thick
paper (1) upper)
H: Temperature set value (Thick
paper (1) lower)
I: Temperature set value (Thick
paper (2) upper)
J: Temperature set value (Thick
paper (2) lower)
K: Temperature set value (OHP
upper)
L: Temperature set value (OHP
lower)
A: Pump ON time
B: Pump interval time
Operation mode
A: Color image density sensor
B: Black image density sensor
C: Target density level (Yellow)
D: Target density level (Magenta)
E: Target density level (Cyan)
F: Target density level (Black)
A: (Black)
B: (Cyan)
C: (Magenta)
D: (Yellow)
Sensor LED level
Dark voltage level
Calibration sheet sense level
Calibration plate sense level
A: Print mode
B: Cyan OPC drum phase
C: Magenta OPC drum phase
D: Yellow OPC drum phase
E: Paper (Paper tray)
Initial setup data
Adjustment value
Correction data
Correction data
Set range
Default
AR-
AR-
C100
C150
70 – 200
70 – 200
70 – 200
70 – 200
70 – 200
70 – 200
70 – 210
70 – 200
70 – 210
70 – 200
70 – 200
70 – 200
5 – 50
12
17 – 250
130
All ON
0 – 200
102
0 – 200
133
0 – 200
90
0 – 200
100
0 – 200
83
0 – 200
15
22
0 – 700
325
0 – 700
325
0 – 700
325
0 – 700
325
0 – 255
128
0 – 255
30
0 – 255
102
0 – 255
80
1 – 3
3
0 – 330
60
0 – 330
120
0 – 330
180
1 – 6
5
0 – 255
40 – 60
50
245 – 755
500
(1 – 1999) ∗1
(1000) ∗1
245 – 755
500
(1 – 1999) ∗1
(1000) ∗1
14 – 11A
Model
NOTE
AR-
AR-
C160/
C250
C270
The set value
(default) differs
depending on the
destination. Refer to
the details of SIM
43-01.
The adjustment value
cannot be entered
directly.
The adjustment value
cannot be entered
directly.
The set up data is
not stored.
The set up data is
not stored.
The set up data
cannot be entered
directly.
The adjustment value
cannot be entered
directly.
The correction data
cannot be entered
directly.
Data store
location
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(ICU PWB)
EEPROM
(ICU PWB)
EEPROM
(ICU PWB)
EEPROM
(ICU PWB)