Choke Rod - Stihl MS 261 User Manual

Hide thumbs Also See for MS 261:
Table of Contents

Advertisement

Installing
2
: Position the torsion spring (1)
and fit it in the lockout lever.
: Push the bushing (2) into the
bore (arrow) – the torsion spring
is held in position.
1
2
– The torsion spring (arrow) must
locate against the tank housing.
: Use a drift (2) to center the
lockout lever (1).
– Drive home the pin until it is
recessed by same amount at
both sides.
– Reassemble all other parts in the
reverse sequence.
– Check operation.
92

10.3.3 Choke Rod

– Remove the air filter, b
1
2
: Move the switch lever (1) in
direction of cold start and hold it
there.
: Pry the choke rod (2) carefully
out of the guide (arrow).
1
: Disconnect the choke rod (1)
from the choke shaft (arrow).
– Check the choke rod and replace
it if necessary
Installing
b 12.1
2
1
: Engage the choke rod (1) in the
bore (arrow) in the choke
shaft (2).
1
2
: Position the choke rod (1) in the
guide (arrow).
– Move the switch lever (2) in
direction of cold start until the
choke rod (1) snaps into position.
– Check operation.
Check that the choke rod is properly
seated.
– Reassemble all other parts in the
reverse sequence.