10.
Control Levers
10.1
Master Control Lever
The positions of the Master Control
lever are described in the instruction
manual.
10.1.1 Removing and Installing
– Remove the air filter, b 12.3
– Remove the choke rod,
b 10.3.3
1
– Set the switch lever (1) to "
: Pry out the switch lever (1) at the
opening (arrow) and lift it slightly.
MS 261, MS 261 C
1
– Remove the short circuit wire (1)
from the switch lever, b
: Remove the switch lever (2),
check it and replace if necessary.
Installing
1
– Place the switch lever (2) in
position.
– Fit the short circuit wire (1) on the
switch lever, b 7.7.2
0
".
: When installing the switch lever,
lift the contact spring (1) a little
– no more than 2 mm.
2
: Push the switch lever (1) onto the
b 7.7.2
filter base's pivot pin (2) until it
snaps into position.
2
: Check operation.
– Short circuit wire's ring terminal
must touch the contact
spring (arrow) in position "
– Reassemble all other parts in the
reverse sequence.
10.2
1
: Push the tabs (1) apart and
through the tank housing.
2
0
".
Throttle Trigger/Lockout
Lever
1
1
1
87