80070603-2B01ffff
Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: IMM has detected a voltage regulator error on the microprocessor and memory expansion tray.
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response:
v CPU 3 VRD: Indicates a problem with either the voltage regulator for CPU3 or CPU 3 itself
v CPU 4 VRD: Indicates a problem with either the voltage regulator for CPU4 or CPU 4 itself
v DIMM 25-30 VRD: Indicates a problem with either the voltage regulator for DIMMs 25-30 or 1 or more of the
following components: DIMM25-DIMM30
v DIMM 31-36 VRD: Indicates a problem with either the voltage regulator for DIMMs 31-36 or 1 or more of the
following components: DIMM31-DIMM36
v DIMM 37-42 VRD: Indicates a problem with either the voltage regulator for DIMMs 37-42 or 1 or more of the
following components: DIMM37-DIMM42
v DIMM 43-48 VRD: Indicates a problem with either the voltage regulator for DIMMs 43-48 or 1 or more of the
following components: DIMM43-DIMM48
1.
Check the IMM Web event log. This event may be a symptom of an earlier error.
2.
Depending on the error perform the following steps.
For a CPU 3 VRD or CPU 4 VRD error:
1. Replace the microprocessor and memory expansion tray.
2. Replace affected microprocessor.
For a DIMM 25-30 VRD, DIMM 31-36 VRD, DIMM 37-42 VRD, or DIMM 43-48 VRD error:
1. Replace DIMM(s) associated with error.
2. Replace the microprocessor and memory expansion tray.
80070608-2584ffff
Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: IMM has detected Power Supply related fault. (PS 12V OC Fault, PS 12V OV Fault, PS 12V UV Fault,
or PS AUX UV Fault)
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response:
1.
Check the power supply LEDs, see "Power-supply LEDs".
2.
Replace the failing power supply.
80070603-2B01ffff • 80070608-2584ffff
Appendix D. Integrated management module II (IMM2) error messages
427

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3750 m4 type 8733

Table of Contents