800b010a-1e86ffff
Redundancy Lost for [RedundancySetElementName] has asserted.
Explanation: Fan Redundancy has been lost.
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 11
Automatically notify Support: No
User response: Replace Fan 6
800b010c-2581ffff
Redundancy Lost for [RedundancySetElementName] has asserted.
Explanation: Backup Memory Redundancy has been lost.
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 41
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
800b0208-1381ffff
Redundancy Degraded for [RedundancySetElementName] has asserted.
Explanation: Power unit is no longer in the redundant state.
Severity: Warning
Alert Category: Warning - Redundant Power Supply
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0804
SNMP Trap ID: 10
Automatically notify Support: No
User response:
1. Check if Power Supply is missing, unplugged.
2. Check the power supply LEDs, see "Power-supply LEDs"
3. Replace the affected power supply.
800b010a-1e86ffff • 800b0208-1381ffff