5.
If problem continues to recur on the same DIMM, re-inspect DIMM connector for foreign material and remove
any foreign material that is found. If the connector is damaged, replace the system board.
6.
Remove the affected processor and inspect the processor socket pins for damaged or mis-aligned pins. If damage
is found, or this is an upgrade processor, replace the system board. If there are multiple processors, swap
processors to move the affected procesor to another processor socket and retry. If problem follows the affected
processor or there is only one processor, replace the affected processor.
7.
Replace the system board.
W.58007
[W.58007] Invalid memory configuration (Unsupported DIMM Population) detected. Please verify
memory configuration is valid.
Explanation: Unsupported DIMM Population
Severity: Warning
User response: Complete the following steps:
1.
Check the event log for any events related to an uncorrectable memory error or failed memory test and resolve
those issues. DIMMs being disabled by other errors or actions could cause this event.
2.
Verify that the DIMMs are installed in the correct population sequence, according to the product documentation
for the system. See the section entitled, "Installing a DIMM" for more information.
W.580A1
[W.580A1] Invalid memory configuration for Mirror Mode. Please correct memory configuration.
Explanation: Unsupported DIMM Population for Mirror Mode
Severity: Warning
User response: Complete the following steps:
1.
If a DIMM error LED is lit, resolve the issue.
2.
Verify that the DIMMs are installed in the correct population sequence for mirroring mode, according to the
product documentation for the system. See the section entitled, "Installing a DIMM" for more information.
W.580A2
[W.580A2] Invalid memory configuration for Sparing Mode. Please correct memory configuration.
Explanation: Unsupported DIMM Population for Spare Mode
Severity: Warning
User response: Verify that the DIMMs are installed in the correct population sequence for sparing mode, according
to the product documentation for the system. See the section entitled, "Installing a DIMM" for more information.
W.68002
[W.68002] A CMOS battery error has been detected
Explanation: A CMOS battery fault was detected.
Severity: Warning
User response: Complete the following steps:
1.
If the system was recently installed, moved, or serviced, make sure that the battery is properly seated.
2.
Check the IBM support site for service bulletins or firmware updates that apply to this error.
3.
Replace the CMOS battery.
4.
Replace the system board.
W.58007 • W.68002
Appendix A. UEFI/POST error codes
315