IBM System x3750 M4 Product Manual
IBM System x3750 M4 Product Manual

IBM System x3750 M4 Product Manual

4-socket server
Hide thumbs Also See for System x3750 M4:

Advertisement

®
IBM System x3750 M4
IBM Redbooks Product Guide
The IBM® System x3750 M4 is a 4-socket server featuring a streamlined design, optimized for price and
performance, with best-in-class flexibility and expandability. Models of the x3750 M4 are powered with
Intel Xeon E5-4600 processors, up to 8 cores each, for an entry-level 4-socket solution. The x3750 M4
provides maximum storage density, with flexible PCI and 10 Gb Ethernet networking options in a 2U form
factor.
Suggested uses : High performance computing (HPC), workloads with floating-point computations, and
small to medium databases requiring fast I/O; applications that require 4-socket performance without
needing the scalability that the IBM eX5 systems provide.
Figure 1. The IBM System x3750 M4
Did you know
The x3750 M4 has outstanding memory performance that is achieved by supporting
three-RDIMM-per-channel configurations at speeds up to 25% faster than the Intel specification, while still
maintaining world-class IBM reliability. LR-DIMM speeds are also 25% beyond the Intel specification for
1.35 V DIMMs, and this speed improve not only performance, but reduces overall system power at the
same time.
The x3750 M4 offers a flexible, scalable design and simple upgrade path to 16 hard-disk drives (HDDs) or
32 IBM eXFlash solid-state drives (SSDs), with up to eight PCIe Gen 3 slots and up to 1.5 TB of memory.
The flexible embedded Ethernet solution provides two standard Gigabit Ethernet ports onboard, along
with a dedicated 10 GbE slot that allows for a choice of either two copper or two fiber optic connections.
Comprehensive systems management tools with the next-generation Integrated Management Module II
(IMM2) make it easy to deploy, integrate, service, and manage.
IBM System x3750 M4
1

Advertisement

Table of Contents
loading

Summary of Contents for IBM System x3750 M4

  • Page 1 The x3750 M4 offers a flexible, scalable design and simple upgrade path to 16 hard-disk drives (HDDs) or 32 IBM eXFlash solid-state drives (SSDs), with up to eight PCIe Gen 3 slots and up to 1.5 TB of memory. The flexible embedded Ethernet solution provides two standard Gigabit Ethernet ports onboard, along with a dedicated 10 GbE slot that allows for a choice of either two copper or two fiber optic connections.
  • Page 2: Key Features

     availability, and a memory capacity of up to 1.5 TB. LR-DIMM speeds implemented in the x3750 M4 are also 25% beyond the Intel specification at 1.35 V  for one, two, and three DIMM per channel configurations. This configuration improves performance...
  • Page 3 (or failing) components, which simplifies servicing, speeds up problem resolution, and helps improve system availability. The x3750 M4 provides error checking and/or Predictive Failure Analysis (PFA) on the following  components. Alerts are generated in advance of a possible failure, therefore increasing uptime.
  • Page 4 Energy efficiency The x3750 M4 offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to a green environment: Energy-efficient planar components help lower operational costs.
  • Page 5: Locations Of Key Components And Connectors

    Locations of key components and connectors The following figure shows the front of the server. Figure 2. Front view of the IBM System x3750 M4 The following figure shows the rear of the server. Figure 3. Rear view of the IBM System x3750 M4...
  • Page 6 The following figure shows the locations of key components inside the server. Figure 4. Inside view of the IBM System x3750 M4 IBM System x3750 M4...
  • Page 7: Standard Specifications

    Slot 5: PCIe 3.0 x8; low profile (requires processor 2)  Slot 6: PCIe 3.0 x8; low profile  Slot 7: PCIe 3.0 x8; low profile  Slot 8: PCIe 3.0 x8; low profile  Slots 1, 2, and 3 are physically x16 slots. IBM System x3750 M4...
  • Page 8 RJ-45 or SFP+ 10 GbE network ports. Internal: Two internal USB ports (for the embedded hypervisor). Cooling IBM Calibrated Vectored Cooling with up to six N+N redundant hot swap fans (all six standard); each fan has two rotors. Power supply Up to two hot-swap redundant 1400 W AC power supplies (80 PLUS Platinum certification).
  • Page 9: Standard Models

    § Model D1x has two RAID controllers, D2x has four RAID controllers total. D1x and D2x include the 512 MB Cache/RAID 5 Upgrade (81Y4484), plus the Battery Kit (81Y4508), plus the SSD Performance Key (90Y4273) for each controller. Refer to the Standards specifications section for information about the standard features of the server. IBM System x3750 M4...
  • Page 10: Processor Options

    Processor options The x3750 M4 supports the processor options listed in the following table. The server supports up to four processors. Two processors are installed in sockets on the system board. Processors 3 and 4 are installed on the processor and memory expansion tray. Most models (with the exception of A2x, as listed in Table 2) have the expansion tray installed as standard.
  • Page 11 DIMMs per channel, as shown under "Max. operating speed" section in the table. Table highlighting: The entries highlighted in indicate that the IBM System x3750 M4 supports higher memory red text  frequencies than the Intel processor specification. In some instances, this configuration also results larger memory capacity that the specification recommends.
  • Page 12 DIMM in each populated channel is reserved as spare memory. The size of a rank varies depending on the DIMMs installed. The following table lists the memory options that are available for the x3750 M4 server. Table 5. Memory options...
  • Page 13: Internal Storage

    SAS expander backplane is connected to the single RAID controller with two cables. All backplane options include the necessary cables. See the IBM System x3750 M4 Installation and Service Guide for a description of all supported backplane combinations.
  • Page 14: Controllers For Internal Storage

    Note: The supported adapters for internal storage need to be installed in slots 1, 2 and 3 because of cable routing requirements. The IBM x3750 M4 PCIe 3x8 riser (88Y7371) must be installed. These slots also require that Processor 2 be installed.
  • Page 15 † The ServeRAID M5100 Series RAID 6 Upgrade (81Y4546) requires RAID 5 upgrades with cache (81Y4484, 81Y4487, or 81Y4559 only). ** Only one ServeRAID Feature on Demand upgrade is required per system, regardless of the number of adapters installed. IBM System x3750 M4...
  • Page 16: Internal Drive Options

    Internal drive options The following table lists the hard disk drive options for the internal disk storage of the x3750 M4 server. Table 9. Disk drive options for internal disk storage (Part 1) Part number Feature Description Maximum code supported 2.5-inch NL SATA Hot-Swap HDDs...
  • Page 17: Internal Backup Units

    41Y8331 A4FL S3700 200GB SATA 2.5" MLC HS Enterprise SSD 2.5-inch SSDs - Enterprise Value 49Y5839 A3AS IBM 64GB SATA 2.5" MLC HS Enterprise Value SSD 49Y5844 A3AU IBM 512GB SATA 2.5" MLC HS Enterprise Value SSD 90Y8643 A2U3 IBM 256GB SATA 2.5" MLC HS Enterprise Value SSD...
  • Page 18: Optical Drives

    Description Maximum Models code supported where used 46M0902 4163 UltraSlim Enhanced SATA Multi-Burner The IBM UltraSlim Enhanced SATA Multi-Burner (46M0902) supports the following media and speeds for reading: CD-ROM 24X  CD-DA (DAE) 20X  CD-R 24X  CD-RW 24X ...
  • Page 19: I/O Expansion Options

    The following table lists the ordering information for the riser card. Table 11. PCI riser card options Part number Feature Description Standard models Maximum code where used supported 88Y7371 A2A1 IBM x3750 M4 PCIe 3 x8 riser B2x, C1x, D1x, D2x IBM System x3750 M4...
  • Page 20: Network Adapters

    Network adapters x3750 M4 supports two integrated Gigabit Ethernet ports. Optionally, two 10 Gb Ethernet ports can be added by installing one of the available dual-port 10 Gb Ethernet cards listed in Table 12 (88Y7429 or 88Y7427). These cards use a dedicated connector on the system board and do not consume a PCI expansion slot.
  • Page 21 (this maximum does not apply to the 10 Gb cards in the dedicated slot). † The IBM x3750 M4 Dual port 10 GB-T Ethernet Adapter Card and IBM x3750 M4 Dual port 10 GB SFP+ Ethernet...
  • Page 22: Storage Host Bus Adapters

    # Maximum quantity is achieved with processor 2 and the 3-slot riser card (88Y7371) installed. With one processor, the maximum quantity is three. * The IBM 6 Gb Performance Optimized HBA (46M0912) is for use only with internal disk storage and requires the IBM x3750 M4 PCIe 3x8 riser (88Y7371) and a second processor to be installed.
  • Page 23: Pcie Ssd Adapters

    For more information, see https://ibm.com/support/entry/myportal/docdisplay?lndocid=SERV-IOMA For details about these adapters, see the IBM Redbooks Product Guide IBM High IOPS SSD PCIe Adapters , found at the following address: http://www.redbooks.ibm.com/abstracts/tips0729.html?Open...
  • Page 24: Power Supplies

    88Y7431 A2A7 IBM 900 W Power Supply 88Y7433 A2EA IBM System x 4S- 750W High Efficiency -48 V DC Power Supply 88Y7367 A2A0 IBM Power Interposer for Redundant Power Supply * The power interposer is not needed if the processor and memory expansion tray (88Y7365) is installed.
  • Page 25: Remote Management

    Remote management The server contains IBM Integrated Management Module II (IMM2), which provides advanced service-processor control, monitoring, and alerting functions. If an environmental condition exceeds a threshold or if a system component fails, the IMM2 lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem.
  • Page 26: Physical And Electrical Specifications

    Maximum configuration: 2.16 kVA (two power supplies)  BTU output:  Minimum configuration: 648 BTU/hr (190 watts)  Maximum configuration: 7,336 BTU/hr (2150 watts)  Noise level:  Idle: 6.5 bels  Operating: 6.6 bels  IBM System x3750 M4...
  • Page 27: Warranty Options

    Warranty options The IBM System x3750 M4 has a three-year on-site warranty with 9x5/next business day terms. IBM offers the warranty service upgrades through IBM ServicePac offerings, described in this section. The IBM ServicePac is a series of prepackaged warranty maintenance upgrades and post-warranty maintenance agreements with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.
  • Page 28: Regulatory Compliance

    GOST R 51317.3.3 IEC 60950-1 (CB Certificate and CB Test Report)  CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, and EN61000-3-3)  CISPR 22, Class A  TUV-GS (EN60950-1 /IEC60950-1,EK1-ITB2000)  RoHS compliance (Directive 2002/95/EC)  IBM System x3750 M4...
  • Page 29: External Disk Storage Expansion

    IBM 2 TB 7200 Dual Port SATA 3.5-in. HS HDD EXP3000 Hot-Swap SAS 3.5-in. Hard Drives 44W2234 IBM 300 GB 15 K 6 Gbps SAS 3.5-in. Hot-Swap HDD 44W2239 IBM 450 GB 15 K 6 Gbps SAS 3.5-in. Hot-Swap HDD 44W2244 IBM 600 GB 15 K 6 Gbps SAS 3.5-in.
  • Page 30 Based on the LSI SAS2208 6 Gbps ROC controller  Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures  For more information, see the IBM Redbooks® Product Guide ServeRAID M5120 SAS/SATA Controller for IBM System x at: http://www.redbooks.ibm.com/abstracts/tips0858.html?Open IBM System x3750 M4...
  • Page 31: External Disk Storage Systems

    External disk storage systems The following table lists the external storage systems that are supported by x3750 M4 and can be ordered through the System x sales channel. The server might support other IBM disk systems that are not listed in this table.
  • Page 32: External Backup Units

    USB Enclosure Adapter Kit 40K2599 SAS Enclosure Adapter Kit Internal backup drives supported by external tape enclosures 43W8478 IBM Half High LTO Gen 3 SAS Tape Drive 44E8895 IBM Half High LTO Gen 4 SAS Tape Drive IBM System x3750 M4...
  • Page 33 LTO Ultrium 3 Half High SAS DriveV2 Sled *The external tape drives listed can be ordered through System x sales channel. The server might support other IBM tape drives that are not listed in this table. See the IBM System Storage Interoperability Center for further information.
  • Page 34: Top-Of-Rack Ethernet Switches

    IBM System Networking - 40 Gb top-of-rack switches 8036ARX IBM System Networking RackSwitch G8316R 8036AFX IBM System Networking RackSwitch G8316F For more information, see the list of IBM Redbooks Product Guides in the Top-of-rack switches category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=tor IBM System x3750 M4...
  • Page 35: Uninterruptible Power Supply Units

    IBM 6000VA LCD 4U Rack UPS (230 V) 53959KX IBM 11000VA LCD 5U Rack UPS (200 V/208 V/230 V) For more information, see the list of IBM Redbooks Product Guides in the Power infrastructure category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=power IBM System x3750 M4...
  • Page 36: Power Distribution Units

    Switched and Monitored PDUs 46M4002 IBM 1U 9 C19/3 C13 Active Energy Manager DPI PDU 46M4003 IBM 1U 9 C19/3 C13 Active Energy Manager 60A 3 Phase PDU 46M4004 IBM 1U 12 C13 Active Energy Manager DPI PDU 46M4005 IBM 1U 12 C13 Active Energy Manager 60A 3 Phase PDU...
  • Page 37 IBM 0U 12 C19/12 C13 60A 3 Phase PDU 46M4143 IBM 0U 12 C19/12 C13 32A 3 Phase PDU For more information, see the list of IBM Redbooks Product Guides in the Power infrastructure category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=power IBM System x3750 M4...
  • Page 38: Rack Cabinets

    IBM 47U 1200 mm Deep Static Rack 99564RX IBM S2 42U Dynamic Standard Rack 99564XX IBM S2 42U Dynamic Standard Expansion Rack For more information, see the list of IBM Redbooks Product Guides in the Rack cabinets and options category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=rack IBM System x3750 M4...
  • Page 39: Rack Options

    IBM Long KVM Conversion Option (4 Pack Long KCO) 46M5383 5341 IBM Virtual Media Conversion Option Gen2 (VCO2) 46M5382 5340 IBM Serial Conversion Option (SCO) For more information, see the list of IBM Redbooks Product Guides in the Rack cabinets and options category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=rack IBM System x3750 M4...
  • Page 40 IBM Global Financing IBM Global Financing can help you obtain the IT solution you need while preserving funding for other strategic investments and optimizing cash flow. Our Fair Market Value (FMV) lease helps ensure that you have the latest IBM technology, and with our mid-lease upgrade capability, you can increase the capacity of the system with little to no change in monthly payments.
  • Page 41: Related Publications And Links

    Integrated Management Module II User's Guide  http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5086346 IBM ServerProven hardware compatibility page for the x3750 M4:  http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/xseries/8722.html IBM Redbooks Product Guides for IBM System x servers and options:  http://www.redbooks.ibm.com/portals/systemx?Open&page=pgbycat Configuration and Option Guide :  http://www.ibm.com/systems/xbc/cog/ xREF - IBM System x Reference Sheets: ...
  • Page 42 Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk.IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
  • Page 43 Intel Xeon, Intel, Intel logo, Intel Inside logo, and Intel Centrino logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. LTO, Ultrium, the LTO Logo and the Ultrium logo are trademarks of HP, IBM Corp. and Quantum in the U.S. and other countries.
  • Page 44 Other company, product, or service names may be trademarks or service marks of others. IBM System x3750 M4...

This manual is also suitable for:

E5-4600

Table of Contents